{"product_id":"schneider-modicon-quantum-140noe77110-communication-module","title":"Schneider Modicon Quantum 140NOE77110 Ethernet Communication Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Modicon Quantum 140NOE77110 is a high-performance Ethernet communication module engineered for the Modicon Quantum automation platform. This module provides robust connectivity to Ethernet TCP\/IP networks, supporting industry-standard protocols such as Modbus TCP and EtherNet\/IP. It acts as a critical interface for integrating PLC systems with supervisory control systems, HMIs, and field devices. Designed for demanding industrial environments including power generation, oil and gas, and mining, the 140NOE77110 features an embedded web server that facilitates remote diagnostics, configuration, and real-time monitoring of process variables, effectively reducing troubleshooting time and minimizing system downtime.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDedicated processor for high-traffic network management, ensuring no impact on CPU scan time.\u003c\/li\u003e\n\u003cli\u003e10\/100 Mbps RJ45 port with auto-negotiation and auto-MDIX capabilities.\u003c\/li\u003e\n\u003cli\u003eSupports advanced networking functions including I\/O scanning, Global Data, and NTP time synchronization.\u003c\/li\u003e\n\u003cli\u003eIntegrated SNMP, BootP, and DHCP for simplified network management and automated IP addressing.\u003c\/li\u003e\n\u003cli\u003eEmbedded Class B30 web server for remote system access and diagnostics.\u003c\/li\u003e\n\u003cli\u003eFlash memory upgradeable to support evolving communication standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe 140NOE77110 is suitable for complex distributed control architectures requiring high-speed data exchange. Typical applications include SCADA system integration, peer-to-peer PLC communication, and remote plant-floor data acquisition in heavy industrial settings.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e140NOE77110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eEthernet TCP\/IP Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rate\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port\u003c\/td\u003e\n\u003ctd\u003e1 x RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols Supported\u003c\/td\u003e\n\u003ctd\u003eModbus TCP, EtherNet\/IP, SNMP, HTTP, FTP, TFTP, DHCP\/BootP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeb Server\u003c\/td\u003e\n\u003ctd\u003eEmbedded (Class B30)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e750 mA at 5 VDC (Internal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95% (Noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the Quantum rack is powered down before inserting or removing the communication module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eSeat the module firmly into the designated slot on the Quantum backplane and secure the locking mechanism.\u003c\/li\u003e\n\u003cli\u003eUse shielded Category 5e or 6 Ethernet cabling to minimize EMI interference in industrial environments.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the control cabinet to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eVerify that the module's IP address and network settings are configured correctly via the web server or software tools before full system integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe 140NOE77110 meets various international standards, including UL, CSA, CE, FM Class I Div 2, and ATEX, making it suitable for use in hazardous location environments where specified.\u003c\/p\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external power?\u003c\/strong\u003e\u003cbr\u003eNo, the 140NOE77110 draws its power directly from the Quantum backplane (750 mA at 5 VDC).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be used for peer-to-peer communication?\u003c\/strong\u003e\u003cbr\u003eYes, the module is designed to support peer-to-peer communication between Modicon Quantum controllers as well as connectivity to third-party SCADA and HMI systems.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":50743435165948,"sku":"140NOE77110","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_85cdbf4a-fd73-4e5a-967c-94c023801505.jpg?v=1785469089","url":"https:\/\/www.electronicplc.com\/es\/products\/schneider-modicon-quantum-140noe77110-communication-module","provider":"Electronic PLC","version":"1.0","type":"link"}