{"product_id":"woodward-9907-076-single-output-power-supply-module","title":"Woodward 9907-076 Single Output Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Woodward 9907-076 is a high-reliability single-output power supply module designed for demanding industrial control environments. This module is engineered to provide stable, consistent power conversion for critical control systems, including power generation, maritime engine management, and petrochemical processing infrastructure. By delivering a reliable 120 V AC\/DC output, the 9907-076 ensures the operational continuity of connected actuators, controllers, and instrumentation, effectively minimizing the risk of unscheduled downtime in mission-critical applications.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Availability Design:\u003c\/strong\u003e Built for continuous operation in harsh industrial environments with high electrical noise and thermal stress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Diagnostics:\u003c\/strong\u003e Features front-panel LED status indicators for real-time monitoring of output health, enabling rapid fault identification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Construction:\u003c\/strong\u003e Heavy-duty chassis design with advanced thermal dissipation paths to maintain voltage stability without requiring active cooling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMI Shielding:\u003c\/strong\u003e Internal circuitry is protected against electromagnetic interference to ensure signal integrity within control racks.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe 9907-076 is widely utilized in Woodward control systems for:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePower generation and distribution control systems.\u003c\/li\u003e\n\u003cli\u003eMaritime engine and turbine control rooms.\u003c\/li\u003e\n\u003cli\u003ePetrochemical and refinery process automation.\u003c\/li\u003e\n\u003cli\u003eCritical infrastructure where high-availability power conversion is required.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e9907-076\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSingle Output Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 V AC \/ 120 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle Output (SGL OUT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Monitoring\u003c\/td\u003e\n\u003ctd\u003eIntegrated LED Indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Always ensure the system rack is de-energized before installing or removing the power supply module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Handling:\u003c\/strong\u003e Use standard electrostatic discharge (ESD) precautions, including a grounded wrist strap, when handling the module to prevent damage to internal components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the module is fully seated within the Woodward control rack and that all retaining screws are tightened to provide a secure ground connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Maintain adequate clearance around the module to allow for passive thermal dissipation; do not obstruct airflow paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Ensure input and output connections are made according to the specific system wiring diagram, utilizing shielded cables where required to maintain EMI immunity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs the Woodward 9907-076 compatible with all Woodward control racks?\u003c\/h3\u003e\u003cp\u003eThe 9907-076 is designed for integration into standard Woodward control racks. Please verify your specific system manual or rack configuration to ensure compatibility with this power supply module.\u003c\/p\u003e\u003ch3\u003eDoes this module require external cooling?\u003c\/h3\u003e\u003cp\u003eNo, the 9907-076 is designed with advanced thermal dissipation paths and does not require active external cooling under standard operating conditions within the specified temperature range of -40 to 70 deg C.\u003c\/p\u003e\u003ch3\u003eWhat do the LED indicators on the front panel signify?\u003c\/h3\u003e\u003cp\u003eThe integrated LEDs provide real-time visual diagnostics for the output status, allowing maintenance personnel to quickly verify that the unit is providing the correct output voltage and to identify potential power fluctuations or failures.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":50730223304956,"sku":"9907-076","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_8588a4b0-10f7-4d48-a94f-5dd9f8550d09.jpg?v=1785212934","url":"https:\/\/www.electronicplc.com\/es\/products\/woodward-9907-076-single-output-power-supply-module","provider":"Electronic PLC","version":"1.0","type":"link"}