{"product_id":"yokogawa-a2smx801-s130-pass-through-i-o-signal-adaptor","title":"YOKOGAWA A2SMX801-S130 Pass-through I\/O Signal Adaptor","description":"\u003cp\u003eConfigured for signal routing within the N-IO system platform, the \u003cstrong\u003eYOKOGAWA A2SMX801-S130\u003c\/strong\u003e (\u003cstrong\u003eA2SMX801-S130\u003c\/strong\u003e Pass-through I\/O Signal Adaptor) provides direct physical execution of I\/O signal mapping. The adaptor serves as a passive interface to connect field instruments and sensors directly to the control system, facilitating data acquisition and control without signal conditioning.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA2SMX801-S130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard N-IO module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (None)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003ePass-through I\/O signal adaptation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eNon-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Field Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe A2SMX801-S130 operates as a non-isolated signal interface component. It is engineered to maintain low-impedance paths between field transmitters and the N-IO system backplane. Because this unit lacks active galvanic isolation, it is designed for environments where field devices are either self-isolated or where ground loop currents are managed via external secondary protection measures. The adaptor ensures consistent 4-20 mA HART loop protocol connectivity by providing a continuous transmission path for digital and analog signal overlays.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this adaptor require external power for operation?\u003c\/p\u003e\n\u003cp\u003eA: No. The A2SMX801-S130 is a passive pass-through device and does not require external power or internal voltage regulation to function.\u003c\/p\u003e\n\u003cp\u003eQ: Can this unit be used as a replacement for isolated signal converters?\u003c\/p\u003e\n\u003cp\u003eA: No. This adaptor provides no galvanic isolation. If the application requires protection against common-mode noise or electrical isolation between the field instrument and the control system, an active signal isolator must be utilized.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify that the N-IO node power is de-energized before installing or replacing the adaptor to prevent accidental short-circuits during terminal engagement.\u003c\/li\u003e\n\u003cli\u003eAlign the adaptor with the designated N-IO baseplate slot. Ensure the locking mechanism is fully engaged to maintain mechanical stability.\u003c\/li\u003e\n\u003cli\u003eTighten all field wiring terminal screws to ensure firm contact and mitigate resistive heating at the connection point.\u003c\/li\u003e\n\u003cli\u003eRoute field instrumentation cables away from high-voltage power lines to prevent induced noise in the non-isolated signal paths.\u003c\/li\u003e\n\u003cli\u003eConfirm that the field device grounding configuration is compatible with a direct-connected, non-isolated signal architecture to minimize ground loop potential.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":50112176324860,"sku":"A2SMX801-S130","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/A2SMX801-S130.jpg?v=1784165736","url":"https:\/\/www.electronicplc.com\/es\/products\/yokogawa-a2smx801-s130-pass-through-i-o-signal-adaptor","provider":"Electronic PLC","version":"1.0","type":"link"}