{"product_id":"yokogawa-csl-amn33-communication-module-nest","title":"Yokogawa CSL\/AMN33 Communication Module Nest","description":"\u003cp\u003eConfigured for high-density interface consolidation in CENTUM control systems, the \u003cstrong\u003eYokogawa CSL\/AMN33\u003c\/strong\u003e (\u003cstrong\u003eAMN33\u003c\/strong\u003e Communication Module Nest) provides direct physical execution for housing and powering communication modules across CENTUM CS 1000, CS 3000, and CENTUM VP platforms. This hardware serves as the primary backplane interface for integrating serialized data streams into distributed control architectures, ensuring mechanical stability and signal path continuity for mission-critical instrumentation.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSL\/AMN33\u003c\/td\u003e\n\u003ctd\u003eBase Communication Module Nest\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCSL\/AMN33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e250 mm (L) x 180 mm (W) x 50 mm (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot applicable (Passive backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM CS 1000, CS 3000, CENTUM VP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Modules\u003c\/td\u003e\n\u003ctd\u003eCommunication Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Instrumentation and Backplane Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe CSL\/AMN33 provides a ruggedized mounting platform designed to maintain electrical connectivity between communication modules and the DCS backplane bus. Its mechanical architecture is engineered to support the operational demands of process control environments, ensuring that inserted modules remain isolated from mechanical shock and thermal variations. The nest incorporates precision-aligned guide slots to facilitate hot-swapping procedures (where supported by the parent system), ensuring that communication paths are maintained with minimal downtime during maintenance cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CSL\/AMN33 include integrated active circuitry for signal processing?\u003c\/p\u003e\n\u003cp\u003eA: No, the CSL\/AMN33 is a passive housing component that provides the necessary physical infrastructure and electrical routing between the communication modules and the host system bus.\u003c\/p\u003e\n\u003cp\u003eQ: Is the AMN33 nest compatible with I\/O modules other than communication modules?\u003c\/p\u003e\n\u003cp\u003eA: The nest is specifically designed and keyed to support the physical and electrical interface requirements of communication modules compatible with CENTUM platforms; it should not be used with standard analog or digital I\/O cards.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the nest securely within the control cabinet to ensure a vibration-free environment, utilizing the provided chassis mounting points.\u003c\/li\u003e\n\u003cli\u003eVerify that the backplane connectors are clear of dust or debris before inserting any communication modules to prevent contact resistance or arcing.\u003c\/li\u003e\n\u003cli\u003eEnsure that all communication module locking mechanisms are fully engaged after insertion to maintain reliable electrical contact with the backplane pins.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified temperature range of -20 deg C to +70 deg C to preserve the integrity of the nest's internal electrical traces and mechanical housing.\u003c\/li\u003e\n\u003cli\u003eObserve standard grounding practices by bonding the nest chassis to the cabinet earth bar to provide an effective shield against electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":50202573275388,"sku":"CSL\/AMN33","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CSLAMN33.jpg?v=1784252689","url":"https:\/\/www.electronicplc.com\/es\/products\/yokogawa-csl-amn33-communication-module-nest","provider":"Electronic PLC","version":"1.0","type":"link"}