{"product_id":"yokogawa-nfai143-s50-s1-analog-input-module","title":"Yokogawa NFAI143-S50 S1 Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa NFAI143-S50 S1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNFAI143\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for multi-channel process variable acquisition within STARDOM control system architectures.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNFAI143\u003c\/strong\u003e: Base model series for 4-channel analog input modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS50\u003c\/strong\u003e: Denotes the standard hardware revision and interface connector configuration for system base plate mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS1\u003c\/strong\u003e: Indicates the specific revision for signal processing and input impedance characteristics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFAI143-S50 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard STARDOM I\/O Module Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e4 independent channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e0 mA to 24 mA (4-20 mA \/ 0-20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and Signal Isolation Integrity\u003c\/h3\u003e\n\u003cp\u003eThe NFAI143-S50 S1 is engineered to maintain high-precision measurement for 4-20 mA HART loop protocol transmitters. The module incorporates automatic cold junction compensation (CJC) logic, which is critical when integrating temperature-derived current signals into the control logic, ensuring that measurement accuracy remains stable despite variations in the ambient cabinet temperature. To maintain data fidelity, the input channels are designed with robust input impedance, preventing signal loading that could cause measurement drift. Furthermore, the 16-bit resolution allows for granular signal tracking, facilitating fine-tuned control over process variables such as flow, pressure, and level.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the NFAI143-S50 S1 support hot-swapping during active operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module is designed for hot-swapping within the STARDOM I\/O rack. Ensure the controller is placed in the designated maintenance mode before extraction to prevent the propagation of invalid process values to the control algorithm.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module be configured for 0-20 mA and 4-20 mA signals simultaneously?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports independent configuration for each of the 4 channels, allowing for mixed signal types across the module inputs. Configuration must be performed via the system software to align the internal A\/D converter scaling.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Secure the module onto the STARDOM DIN-rail base plate. Ensure the locking latch is fully engaged to establish a reliable connection to the backplane communication bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring\u003c\/strong\u003e: Use twisted-pair shielded cabling to connect field instruments. To maintain signal integrity, terminate the shield at the cabinet ground bar, ensuring the path to ground is low-impedance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: The module must share a common ground reference with the DCS cabinet to prevent potential differences that could manifest as common-mode noise in the analog input signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management\u003c\/strong\u003e: While rated for -20 deg C to 70 deg C, avoid placement near high-heat components. Maintain unobstructed airflow to ensure consistent thermal conditions for the CJC circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49534963024124,"sku":"NFAI143-S50 S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/NFAI143-S501.jpg?v=1780882796","url":"https:\/\/www.electronicplc.com\/es\/products\/yokogawa-nfai143-s50-s1-analog-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}