{"product_id":"10020-1-2-honeywell-cpu-module","title":"10020\/1\/2 Honeywell CPU Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 10020\/1\/2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the core\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCentral Processor Unit (CPU)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFail-Safe Control (FSC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem, responsible for executing critical safety logic and synchronizing all I\/O modules. Designed for high-integrity industrial applications, it ensures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeterministic timing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereliable safety-instrumented functions (SIF)\u003c\/strong\u003e. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory stock\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure optimal performance and certification integrity for your safety loops.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10020\/1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCentral Processor Unit (CPU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 cm x 12.7 cm x 20.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% Brand New, Original\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArchitecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFail-Safe Control (FSC) System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Logic Execution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsures fixed scan times for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eESD\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF\u0026amp;G\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecycles, independent of network load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Self-Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eContinuously monitors internal hardware, memory integrity, and clock synchronization to detect faults early.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow-Power High-Performance Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompact\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2.5 cm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efootprint with low thermal output, reducing cooling requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Backplane Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-speed data transmission between the CPU and remote I\/O modules for stable signal integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDifference between the 10020\/1\/2 and other 10020 revisions?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/1\/2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erevision specifies a unique hardware and memory configuration. Ensure compatibility with your system's firmware and backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support redundant CPU configurations?\u003c\/strong\u003e\u003cbr\u003eYes, dual\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10020\/1\/2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules can be installed in a redundant setup for high availability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I load the safety program?\u003c\/strong\u003e\u003cbr\u003eUse\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Safety Builder\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware to compile and download the program. It is stored in non-volatile memory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat visual indicators are available?\u003c\/strong\u003e\u003cbr\u003eThe front panel includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLED indicators\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor operational mode (Run, Stop, Fault) and internal bus activity status.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48947770720508,"sku":"10020\/1\/2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/10020122.jpg?v=1775633091","url":"https:\/\/www.electronicplc.com\/products\/10020-1-2-honeywell-cpu-module","provider":"Electronic PLC","version":"1.0","type":"link"}