{"product_id":"125840-02-bently-nevada-3500-15-low-voltage-ac-power-input-module-2","title":"Bently Nevada 128229-01 Proximitor \/ Seismic I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 128229-01 is a Proximitor\/Seismic I\/O module designed for integration with the 3500\/42M series machinery protection system. This module serves as the interface for four channels, accepting inputs from both proximity and seismic transducers. It conditions these signals to provide critical vibration and position measurements, which are then compared against user-programmable alarm setpoints to ensure reliable machinery protection and operational monitoring.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFour-channel monitoring capability.\u003c\/li\u003e\n\u003cli\u003eCompatible with proximity and seismic transducer inputs.\u003c\/li\u003e\n\u003cli\u003eInternal termination design for streamlined wiring.\u003c\/li\u003e\n\u003cli\u003eSupports continuous machinery protection and diagnostic data acquisition.\u003c\/li\u003e\n\u003cli\u003eDesigned for seamless integration with the 3500 series rack architecture.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOil \u0026amp; Gas:\u003c\/strong\u003e Monitoring for upstream platforms, midstream pipelines, and downstream refineries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Generation:\u003c\/strong\u003e Essential for steam, gas, and hydro turbine protection in traditional and combined-cycle plants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePetrochemicals:\u003c\/strong\u003e Safeguarding high-speed reactors, compressors, and mixers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMining \u0026amp; Metals:\u003c\/strong\u003e Monitoring large-scale rotating equipment such as conveyors, crushers, and rolling mills.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e128229-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eProximitor \/ Seismic I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e-10 Vdc to +10 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Power Supply\u003c\/td\u003e\n\u003ctd\u003e-24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10.5 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Type\u003c\/td\u003e\n\u003ctd\u003eInternal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Precautions:\u003c\/strong\u003e Always use a grounded anti-static wrist strap when handling the module to prevent damage to sensitive internal circuitry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e The I\/O module must be installed in the rear slot directly behind its corresponding 3500\/42M monitor module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecuring:\u003c\/strong\u003e Slide the module into the rack and tighten the two captive screws to ensure a secure connection to the backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBulkhead Racks:\u003c\/strong\u003e For bulkhead-style rack configurations, the I\/O module is positioned above the monitor module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e Ensure the system power is disconnected before inserting or removing any I\/O modules to prevent electrical faults.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 128229-01?\u003c\/h3\u003e\u003cp\u003eThe 128229-01 is a Proximitor\/Seismic I\/O module with internal terminations, specifically engineered to interface with Bently Nevada 3500\/42M monitors to provide machinery protection through vibration and position signal conditioning.\u003c\/p\u003e\u003ch3\u003eWhere should this module be installed?\u003c\/h3\u003e\u003cp\u003eThis module must be installed in the rear slot of the 3500 rack, directly behind the associated 3500\/42M monitor module. For bulkhead-mounted racks, it is installed above the monitor.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50643888931068,"sku":"128229-01","price":80.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_de8cad3d-5e94-44fb-be0f-a8eda2b87f8e.jpg?v=1784952178","url":"https:\/\/www.electronicplc.com\/products\/125840-02-bently-nevada-3500-15-low-voltage-ac-power-input-module-2","provider":"Electronic PLC","version":"1.0","type":"link"}