{"product_id":"140cpu67160-schneider-electric-modicon-quantum-plc-processor-module","title":"140CPU67160 Schneider Electric Modicon Quantum PLC Processor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140CPU67160\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUnity Hot Standby (HSBY) processor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the Modicon Quantum automation platform by Schneider Electric. Designed for mission-critical applications, it provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eseamless redundancy\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethrough real-time synchronization between primary and standby controllers, ensuring uninterrupted process control in the event of hardware failure.\u003c\/p\u003e\n\u003cp\u003eOperating within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUnity Pro \/ EcoStruxure Control Expert\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenvironment, the 140CPU67160 supports complex control logic, large I\/O architectures, and high-speed communications. It integrates an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEthernet port\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus serial interface\u003c\/strong\u003e, and a dedicated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efiber optic synchronization port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor Hot Standby operation.\u003c\/p\u003e\n\u003cp\u003eWith strong processing capability and rapid scan times, this processor is widely used in high-availability systems across oil \u0026amp; gas, water treatment, and power generation sectors.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e140CPU67160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eIntegrated Hot Standby (HSBY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClock Speed\u003c\/td\u003e\n\u003ctd\u003e266 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Memory\u003c\/td\u003e\n\u003ctd\u003e1024 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Memory\u003c\/td\u003e\n\u003ctd\u003e768 KB RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Requirement\u003c\/td\u003e\n\u003ctd\u003eOccupies 2 Quantum slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eLED indicators (Ready, Run, Error, Modbus, Ethernet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eThe 140CPU67160 is typically deployed in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEmergency Shutdown Systems (ESD)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous chemical processing units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMunicipal water pumping stations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn a Hot Standby configuration, if the primary CPU detects a fault, the standby processor takes control within milliseconds, preventing process interruption or unsafe operating conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What software is required for programming?\u003c\/strong\u003e\u003cbr\u003eThe processor requires\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUnity Pro (v2.0 or higher)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEcoStruxure Control Expert\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Is a special cable required for Hot Standby synchronization?\u003c\/strong\u003e\u003cbr\u003eYes. A\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ededicated fiber optic synchronization cable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis required to connect the Sync ports of the primary and standby CPUs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can this processor operate in standalone mode?\u003c\/strong\u003e\u003cbr\u003eYes. Although optimized for redundancy, it can function as a high-capacity standalone Quantum processor when Hot Standby is not configured.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":48746747855100,"sku":"140CPU67160","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/140CPU67160_ae7ab628-553d-4aba-9e2c-22c24dd6b121.jpg?v=1772610735","url":"https:\/\/www.electronicplc.com\/products\/140cpu67160-schneider-electric-modicon-quantum-plc-processor-module","provider":"Electronic PLC","version":"1.0","type":"link"}