{"product_id":"330930-060-00-00-bently-nevada-3300-xl-standard-extension-cable","title":"Bently Nevada 3300\/35-05-02-01-00-00 6-Channel Temperature Monitor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/35 Temperature Monitor is a rack-mounted module designed to measure multiple temperature points in turbines, compressors, and other critical rotating machinery. The 05 suffix option specifies a 6-channel configuration, supporting both RTD and thermocouple inputs. It continuously compares temperature readings against alarm setpoints, providing early warning of abnormal thermal conditions and enabling predictive maintenance.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSix independent input channels for comprehensive thermal monitoring.\u003c\/li\u003e\n\u003cli\u003eSupports a wide range of sensor types including RTDs (Pt100, Pt1000) and thermocouples (J, K, T types).\u003c\/li\u003e\n\u003cli\u003eIntegrated alarm logic with Alert and Danger setpoints.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators for system status: OK, Bypass, Alert, and Danger.\u003c\/li\u003e\n\u003cli\u003eStandard relay outputs for direct integration with plant safety and control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is primarily used in industrial environments for monitoring bearing temperatures, stator windings, and equipment casings in large rotating machinery such as gas and steam turbines, centrifugal compressors, and large electric motors.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/35-05-02-01-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003eRTD (Pt100, Pt1000), Thermocouple (J, K, T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.5% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 1-5 VDC, Relay (Alert\/Danger)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the rack system to mitigate EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for all sensor inputs to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eVerify that sensor wiring matches the configured input type (RTD vs. Thermocouple) before applying power.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the rack to ensure operating temperatures remain within the specified -35 degC to +65 degC range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat sensor types are compatible with this module?\u003c\/h3\u003e\u003cp\u003eThis specific model supports RTDs (Pt100 and Pt1000) and standard J, K, and T type thermocouples.\u003c\/p\u003e\u003ch3\u003eDoes this module require external barriers?\u003c\/h3\u003e\u003cp\u003eThe 00 suffix in the barrier option position indicates that this unit is configured with standard input barriers; ensure your installation environment complies with hazardous area requirements if applicable.\u003c\/p\u003e\u003ch3\u003eHow are the alarm setpoints configured?\u003c\/h3\u003e\u003cp\u003eAlarm setpoints for Alert and Danger conditions are configured through the Bently Nevada 3300 system interface, allowing for independent thresholds per channel.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50912523092220,"sku":"3300\/35-05-02-01-00-00","price":80.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_492eb5c1-2e9e-4f2d-bc66-9a958b92db5b.jpg?v=1785748590","url":"https:\/\/www.electronicplc.com\/products\/330930-060-00-00-bently-nevada-3300-xl-standard-extension-cable","provider":"Electronic PLC","version":"1.0","type":"link"}