{"product_id":"3601e-triconex-digital-output-module","title":"Triconex 3601E Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Triconex 3601E digital output module is a high-integrity control interface designed for AC loads within a Triple Modular Redundancy (TMR) safety-instrumented system. Featuring 16 non-commoned, opto-isolated output points, this module provides reliable switching for high-voltage field actuators, motor starters, and critical solenoids. It is engineered for safety-critical applications in demanding environments, including oil and gas, power generation, and mining, where it prevents fault migration and minimizes spurious trips.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 independent, non-commoned output channels for flexible wiring configurations.\u003c\/li\u003e\n\u003cli\u003eTriple Modular Redundancy (TMR) architecture with 2-out-of-3 (2oo3) internal voting logic.\u003c\/li\u003e\n\u003cli\u003eFull optical isolation between field output points and the internal system backplane.\u003c\/li\u003e\n\u003cli\u003eSupports online hot-swapping for maintenance without system downtime.\u003c\/li\u003e\n\u003cli\u003eVisual identification via green front-panel coding.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe 3601E is intended for use in safety-critical control loops where high availability and fault tolerance are required. Typical applications include emergency shutdown systems (ESD), fire and gas monitoring, and critical process control where AC load switching is necessary.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3601E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTriconex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e16 (Non-commoned)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e115 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e80-155 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOpto-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10 W (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the Triconex chassis is powered down before inserting or removing the module unless performing a hot-swap in a supported, energized environment.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for field connections to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eVerify that the field wiring matches the non-commoned configuration requirements of the 16 channels.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation within the cabinet to ensure the module operates within the 0 to 60 deg C temperature range.\u003c\/li\u003e\n\u003cli\u003eHandle with care to prevent electrostatic discharge (ESD) damage to the internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs the 3601E module hot-swappable?\u003c\/h3\u003e\u003cp\u003eYes, the 3601E is designed for online hot-swapping, allowing for replacement or maintenance while the Triconex system remains in operation, provided the installation environment supports this procedure.\u003c\/p\u003e\u003ch3\u003eWhat does the non-commoned output configuration mean?\u003c\/h3\u003e\u003cp\u003eNon-commoned outputs mean that each of the 16 channels has its own independent return path. This allows for greater flexibility in wiring, including the ability to use mixed-phase AC power sources for different channels.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":50775019028732,"sku":"3601E","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_34324be2-12cf-45ba-90fe-25c9b9015570.jpg?v=1785491870","url":"https:\/\/www.electronicplc.com\/products\/3601e-triconex-digital-output-module","provider":"Electronic PLC","version":"1.0","type":"link"}