{"product_id":"5301-mbp-dfcm-prosoft-protocol-communication-module","title":"5301-MBP-DFCM ProSoft Protocol Communication Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5301-MBP-DFCM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance industrial protocol gateway developed by ProSoft Technology. It enables seamless bidirectional communication between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus Plus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enetworks and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDF1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserial networks, serving as a critical integration bridge in mixed-controller automation environments.\u003c\/p\u003e\n\u003cp\u003eThis module allows Rockwell Automation Allen-Bradley PLCs using DF1 protocol to communicate directly with Schneider Electric Modicon controllers and other Modbus Plus devices. It eliminates the need for complex ladder logic programming or custom protocol drivers by handling data translation internally.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5301-MBP-DFCM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emaps Modbus Plus global database registers to DF1 asynchronous serial frames, making it ideal for legacy system integration, phased modernization projects, and multi-vendor controller synchronization.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e5301-MBP-DFCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eModbus Plus to DF1 protocol conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Ports\u003c\/td\u003e\n\u003ctd\u003e1 × Modbus Plus port, 1 × Multi-protocol Serial Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Standards\u003c\/td\u003e\n\u003ctd\u003eRS-232, RS-422, RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDF1 Modes\u003c\/td\u003e\n\u003ctd\u003eFull Duplex and Half Duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Plus Features\u003c\/td\u003e\n\u003ctd\u003eGlobal Data access, Peer-to-Peer messaging (MSTR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e800 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN-rail or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5301-MBP-DFCM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWater and wastewater treatment facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; gas pipeline monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomotive and heavy manufacturing lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is particularly valuable where legacy SLC 500 or MicroLogix controllers must interface with an existing Modbus Plus backbone infrastructure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module act as a Master on both networks simultaneously?\u003c\/strong\u003e\u003cbr\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5301-MBP-DFCM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports flexible Master\/Slave configurations on both Modbus Plus and DF1 networks, allowing it to actively poll data and issue commands as required by the system architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software is required for initial configuration?\u003c\/strong\u003e\u003cbr\u003eConfiguration is typically performed using ProSoft Configuration Builder (PCB) or a standard terminal emulation program. Users define register mappings, communication parameters, and protocol behavior during setup.\u003c\/p\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":48746754670844,"sku":"5301-MBP-DFCM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5301-MBP-DFCM_bf1145aa-eeb6-4410-af03-390b19820faf.jpg?v=1772436756","url":"https:\/\/www.electronicplc.com\/products\/5301-mbp-dfcm-prosoft-protocol-communication-module","provider":"Electronic PLC","version":"1.0","type":"link"}