{"product_id":"5437-523-woodward-analog-field-terminal-module","title":"5437-523  Woodward Analog Field Terminal Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5437-523\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Analog Field Terminal Module (FTM) developed by Woodward, Inc. for use within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol platform.\u003c\/p\u003e\n\u003cp\u003eThis module provides high-density analog signal interfacing between field instrumentation and VMEbus-based control processors. It enables accurate acquisition and conditioning of low-level analog signals from sensors such as temperature, pressure, and flow transmitters used in turbine and engine control systems.\u003c\/p\u003e\n\u003cp\u003eThe module features high electrical isolation, high input impedance, and strong electromagnetic interference resistance, ensuring reliable operation in harsh industrial environments such as power generation plants and mechanical drive systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5437-523\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Field Terminal Module (FTM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExcitation Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5% full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCMRR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-90 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kHz bandwidth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroNet VMEbus control link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 × 89 × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGas and steam turbine monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation plant control cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-density analog instrumentation integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDistributed DCS \/ SCADA monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with MicroNet Simplex and Plus systems?\u003c\/strong\u003e\u003cbr\u003eYes, but ensure the backplane and cabling support the VMEbus interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of 1500 VAC isolation?\u003c\/strong\u003e\u003cbr\u003eIt protects the control system from electrical surges and prevents ground loop signal errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it supply sensor power?\u003c\/strong\u003e\u003cbr\u003eYes. The module provides 2 mA excitation current for compatible transducers.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746772594940,"sku":"5437-523","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5437-523.jpg?v=1772006489","url":"https:\/\/www.electronicplc.com\/products\/5437-523-woodward-analog-field-terminal-module","provider":"Electronic PLC","version":"1.0","type":"link"}