{"product_id":"5463-785-analog-input-module-woodward","title":"5463-785 Analog Input Module  Woodward","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5463-785\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density Analog Input (AI) module developed by Woodward, Inc. for use in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNetcon\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edigital control platforms.\u003c\/p\u003e\n\u003cp\u003eThis module serves as a high-precision interface between field instrumentation and the control CPU, converting continuous analog signals into digital data for real-time control of turbines, engines, and other industrial machinery. It supports sensors such as pressure transmitters, temperature monitoring systems, and flow measurement devices.\u003c\/p\u003e\n\u003cp\u003eThe module features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehardware-level signal conditioning\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto reduce EMI and electrical noise interference common in power generation and engine room environments. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVME-based architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures fast data communication with the controller processor, while its calibration-free design reduces long-term maintenance requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5463-785\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Input (AI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 independent channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20 mA or 0–5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1% full scale (room temperature)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between field and logic circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 ms (system cycle synchronized)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Ω (current loop)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.1 × 2.5 × 23.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTurbine control parameter monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil and gas process automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower plant instrumentation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEngine governing feedback loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support thermocouple or RTD inputs?\u003c\/strong\u003e\u003cbr\u003eNo. Thermocouples and RTDs require dedicated signal conditioners or specialized temperature input modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the module hot-swappable?\u003c\/strong\u003e\u003cbr\u003eIn many MicroNet Plus systems, yes. However, always follow chassis-specific maintenance procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a signal wire breaks?\u003c\/strong\u003e\u003cbr\u003eThe module detects signal loss when current drops below 3 mA and reports a fault to the CPU for safe control action.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746772136188,"sku":"5463-785","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5463-785.jpg?v=1772006487","url":"https:\/\/www.electronicplc.com\/products\/5463-785-analog-input-module-woodward","provider":"Electronic PLC","version":"1.0","type":"link"}