{"product_id":"5501-365-woodward-analog-input-output-module","title":"5501-365 Woodward Analog Input\/Output Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 5501-365\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density Analog Input\/Output (I\/O)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet Plus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol platforms. It acts as the primary interface between the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edigital controller\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand field instrumentation in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial turbine\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eengine control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems. The module manages the acquisition of critical sensor data (such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epressures\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etemperatures\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epositions\u003c\/strong\u003e) while simultaneously driving\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eproportional actuators\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evalves\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eUnlike end-element converters, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-365\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erack-mounted electronic PCB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat provides the necessary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esignal conditioning\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egalvanic isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor precise\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGovernor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efuel control loops\u003c\/strong\u003e. It features high-speed sampling rates and sophisticated on-board diagnostics to monitor for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eopen circuits\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esignal out-of-range\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efaults, ensuring the highest levels of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esystem integrity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emechanical drive\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eapplications.\u003c\/p\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5501-365\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlatform Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroNet \/ MicroNet Plus \/ MicroNet Simplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Input and Output (Combined I\/O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channel Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Range (I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoftware-configurable 4–20 mA or 0–5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal 24 VDC (via backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-speed parallel backplane bus (RS-485 for specialized diagnostics)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14-bit or 16-bit A\/D and D\/A converters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 Vrms (Field-to-Logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSynchronized with CPU task rate (as fast as 5 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10°C to +60°C (Internal rack ambient)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 50 mm x 30 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e 0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Application Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-365\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis typically used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egas turbine control systems\u003c\/strong\u003e, where it monitors parameters such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emanifold pressure\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eexhaust temperature\u003c\/strong\u003e, while simultaneously controlling\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efuel valve position\u003c\/strong\u003e. Its ability to handle both inputs and outputs on a single card makes it an efficient solution for reducing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echassis space\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein mid-sized control architectures.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003ch4\u003eCan I mix 4-20 mA and 0-5V signals on the same module?\u003c\/h4\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-365\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindependent channel configuration\u003c\/strong\u003e, allowing you to mix signal types as required by your specific instrumentation setup.\u003c\/p\u003e\n\u003ch4\u003eIs this module hot-swappable?\u003c\/h4\u003e\n\u003cp\u003eWhen used in a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet Plus chassis\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith the appropriate software version, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-365\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehot-replacement\u003c\/strong\u003e. However, standard safety procedures should always be followed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eturbine control systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003eHow does the module handle sensor failure?\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-365\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eloop monitoring\u003c\/strong\u003e. If a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4–20 mA signal\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edrops below\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4 mA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(indicating a wire break), the module flags a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efault bit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPU\u003c\/strong\u003e, allowing the system to initiate a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esafe shutdown\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor switch to a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant sensor\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746762436860,"sku":"5501-365","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5501-3651.jpg?v=1772175918","url":"https:\/\/www.electronicplc.com\/products\/5501-365-woodward-analog-input-output-module","provider":"Electronic PLC","version":"1.0","type":"link"}