{"product_id":"5501-367-woodward-analog-i-o-control-module","title":"5501-367 Woodward Analog I\/O Control Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 5501-367\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprecision analog interface module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet Plus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol platforms. This module acts as a critical bridge between the digital processing core and field instrumentation, enabling the acquisition of sensor data and execution of actuator commands simultaneously. It is specifically engineered for high-speed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eturbine control loops\u003c\/strong\u003e, where\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esignal latency\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eresolution\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare crucial for system stability and fuel efficiency.\u003c\/p\u003e\n\u003cp\u003eUnlike standard industrial I\/O modules, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-367\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egalvanic isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efiltering\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto eliminate\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eground loop interference\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein complex power generation environments. Each channel is individually calibrated to maintain\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh linearity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacross the entire signal range, supporting a variety of current-loop and voltage-based transducers. The module is optimized for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet backplane\u003c\/strong\u003e, allowing for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eseamless hot-swapping\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eautomatic configuration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eduring system maintenance.\u003c\/p\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5501-367\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Input\/Output (I\/O) Expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiple 4–20 mA or 0–5 VDC configurable inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20 mA proportional outputs for actuator and valve control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit to 16-bit (Configuration dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField-to-Logic isolation rated for 500 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSynchronized with MicroNet CPU task cycles (typically 5ms to 10ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-board Diagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuous monitoring for open loops and out-of-range signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 cm x 12.4 cm x 12.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Application Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-367\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis primarily deployed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egas\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esteam turbine management systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere it monitors critical parameters like\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eexhaust temperatures\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efuel pressures\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evalve positions\u003c\/strong\u003e. It is also frequently used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elarge-scale compressor control trains\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto manage\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanti-surge valve modulation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003ch4\u003eDoes this module support both current and voltage signals?\u003c\/h4\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-367\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis versatile and can support both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecurrent\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evoltage signals\u003c\/strong\u003e. Specific channel types are determined by jumper settings on the module or software configuration in the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward GAP®\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenvironment.\u003c\/p\u003e\n\u003ch4\u003eIs this compatible with the MicroNet Plus redundant chassis?\u003c\/h4\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-367\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis fully compatible with both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSimplex\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePlus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003echassis architectures, supporting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant I\/O configurations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor high-reliability applications.\u003c\/p\u003e\n\u003ch4\u003eWhat diagnostic feedback does the module provide?\u003c\/h4\u003e\n\u003cp\u003eThe module reports status bits to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPU\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor every channel, identifying fault conditions such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecurrent loop breaks\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(4mA underflow) or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esensor saturation\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746762502396,"sku":"5501-367","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5501-3671.jpg?v=1772175918","url":"https:\/\/www.electronicplc.com\/products\/5501-367-woodward-analog-i-o-control-module","provider":"Electronic PLC","version":"1.0","type":"link"}