{"product_id":"6es7134-4gb01-0ab0-siemens-simatic-dp-ai-module","title":"Siemens 6ES7134-4GB01-0AB0 SIMATIC DP ET 200S Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Siemens 6ES7134-4GB01-0AB0 is a SIMATIC DP electronic module for the ET 200S distributed I\/O system. This 2-channel analog input module (2AI I-2DMU ST) is designed to process standard 4 to 20 mA current signals from 2-wire transducers. With a compact 15 mm width, it is engineered for high-density I\/O configurations in industrial automation environments, providing reliable data acquisition for pressure, flow, and level monitoring applications.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2-channel analog current input for 2-wire transducers (4-20 mA).\u003c\/li\u003e\n\u003cli\u003e13-bit resolution with a cycle time of 65 ms per channel.\u003c\/li\u003e\n\u003cli\u003eUltra-compact 15 mm module width for space-saving ET 200S rack assemblies.\u003c\/li\u003e\n\u003cli\u003eIntegrated diagnostic SF (Group Fault) LED for rapid status identification.\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection with a destruction limit of 35 mA per channel.\u003c\/li\u003e\n\u003cli\u003eParameterizable digital smoothing and filtering capabilities.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWater and wastewater treatment monitoring (pressure and dosing levels).\u003c\/li\u003e\n\u003cli\u003eChemical and petrochemical process instrumentation.\u003c\/li\u003e\n\u003cli\u003eMarine and maritime auxiliary monitoring systems.\u003c\/li\u003e\n\u003cli\u003eHydrostatic and differential pressure measurement.\u003c\/li\u003e\n\u003cli\u003eFlow tracking via electromagnetic or vortex flow meters.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6ES7134-4GB01-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Current (2-wire transducer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e13-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCycle Time\u003c\/td\u003e\n\u003ctd\u003e65 ms per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (via power module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption (Load)\u003c\/td\u003e\n\u003ctd\u003eMax 80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption (Backplane)\u003c\/td\u003e\n\u003ctd\u003eMax 10 mA (3.3 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e0.6 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddress Space\u003c\/td\u003e\n\u003ctd\u003e4 bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 35 mm DIN rail is securely mounted horizontally within the enclosure.\u003c\/li\u003e\n\u003cli\u003eSnap the terminal module onto the DIN rail and slide it laterally to engage with the adjacent ET 200S interface or power module.\u003c\/li\u003e\n\u003cli\u003eAlign the 6ES7134-4GB01-0AB0 electronic module with the terminal module guide rails and press firmly until it clicks into place.\u003c\/li\u003e\n\u003cli\u003eAlways power down the system before inserting or removing electronic modules to prevent electrical damage or bus communication errors.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding and shielding practices for analog signal cabling to minimize EMI interference.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003ch3\u003eWhat is the current consumption of the 6ES7134-4GB01-0AB0 module?\u003c\/h3\u003e\u003cp\u003eThe module draws a maximum of 80 mA from the 24 V load power supply (L+) and 10 mA from the 3.3 V backplane bus.\u003c\/p\u003e\u003ch3\u003eWhat type of signals does this module accept?\u003c\/h3\u003e\u003cp\u003eThis module is specifically designed for 2-wire transducers providing a 4 to 20 mA analog current signal.\u003c\/p\u003e\u003ch3\u003eWhat does the SF LED indicate?\u003c\/h3\u003e\u003cp\u003eThe SF (Group Fault) LED provides a visual indication of group-level errors, such as open circuits or internal module faults.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":50738896535804,"sku":"6ES7134-4GB01-0AB0","price":80.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_c3b082bc-010c-4bce-88c1-a8696c0b8f9f.jpg?v=1785383657","url":"https:\/\/www.electronicplc.com\/products\/6es7134-4gb01-0ab0-siemens-simatic-dp-ai-module","provider":"Electronic PLC","version":"1.0","type":"link"}