{"product_id":"8c-tdil51-honeywell-digital-input-termination","title":"8C-TDIL51 Honeywell Digital Input Termination","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe 8C-TDIL51 is a high-density Input Output Termination Assembly (IOTA) engineered for the Honeywell Experion PKS Series 8. It serves as the primary electrical interface for Series 8 digital input modules, providing secure termination points for 24 VDC field wiring. This allows discrete field devices—such as limit switches, sensors, and pushbuttons—to connect reliably to the I\/O module for processing by the control system.\u003c\/p\u003e\n\u003cp\u003eDesigned for high-availability industrial environments, the 8C-TDIL51 features a vertical mounting profile that maximizes cabinet density while supporting natural convection cooling. Its robust terminal blocks ensure long-term connection integrity under conditions such as vibration and thermal cycling. By centralizing field terminations and module mounting, the assembly simplifies wiring, reduces installation effort, and maintains stable signal integrity across the Distributed Control System (DCS).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003e8C-TDIL51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Type\u003c\/td\u003e\n\u003ctd\u003eInput Output Termination Assembly (IOTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Family\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Module\u003c\/td\u003e\n\u003ctd\u003e8C-PDIL51 Digital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Channels\u003c\/td\u003e\n\u003ctd\u003e32 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd\u003eVertical Cabinet Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew or Compression (variant-dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Height\u003c\/td\u003e\n\u003ctd\u003e12.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Width\u003c\/td\u003e\n\u003ctd\u003e2.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Depth\u003c\/td\u003e\n\u003ctd\u003e12.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe 8C-TDIL51 is widely used in industrial automation environments such as:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePetrochemical refining\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePharmaceutical manufacturing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTypical applications include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTerminating safety interlock feedback signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnecting motor status and auxiliary contacts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupporting general discrete alarm and monitoring inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt provides the physical and electrical foundation for reliable digital input acquisition within a Series 8 control cabinet in a Distributed Control System (DCS).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 8C-TDIL51 support redundant module configurations?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. This version is typically a simplex (non-redundant) termination assembly. For redundancy, a dual-slot IOTA designed to accommodate two 8C-PDIL51 modules is required within the Honeywell Experion PKS Series 8 architecture.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48868370252028,"sku":"8C-TDIL51","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/8C-TDIL51_51306969-175.jpg?v=1773903458","url":"https:\/\/www.electronicplc.com\/products\/8c-tdil51-honeywell-digital-input-termination","provider":"Electronic PLC","version":"1.0","type":"link"}