{"product_id":"900a16-0301-honeywell-16-channel-high-level-analog-input-module","title":"900A16-0301 Honeywell 16-Channel High-Level Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 900A16-0301\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density, high-level analog input\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControlEdge HC900\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLC platforms\u003c\/strong\u003e. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 independent channels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor monitoring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evoltage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecurrent\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignals from field transmitters such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eflow meters\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epressure sensors\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elevel gauges\u003c\/strong\u003e. This module ensures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprecise data acquisition\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emaximum uptime\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor industrial control strategies by leveraging advanced signal processing technologies. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal hardware to guarantee reliability and optimal performance in demanding environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e900A16-0301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-Level Analog Input (AI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage (e.g., 1-5V) or Current (4-20mA via external shunt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-Bit A\/D Converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanically isolated point-to-chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShunt Resistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports 250-ohm shunt resistors per channel for current sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C (standard) \/ -40°C to 70°C (extended range models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLED Module Status (Green\/Red\/Amber)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Channel Layout\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-channel architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows engineers to consolidate high-level analog signals into fewer rack slots. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eefficiency\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enot only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereduces overall chassis requirements\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebut also lowers the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecost-per-point\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor large-scale data acquisition projects, particularly when handling significant numbers of field transmitters in industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Protection\u003c\/strong\u003e\u003cbr\u003eEach point features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egalvanic isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto the chassis, preventing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eground loops\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand protecting the internal backplane circuitry from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efield-side electrical interference\u003c\/strong\u003e. This design ensures that any faults in one field transmitter do not affect the integrity of the entire control system, enhancing overall system reliability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Signal Handling\u003c\/strong\u003e\u003cbr\u003eThe module is designed to support\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eboth voltage and current inputs\u003c\/strong\u003e. For current-based loops (4-20mA), engineers can easily add\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e250-ohm precision shunt resistors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto the terminal block, enabling consistent signal processing across a wide variety of industrial instrument types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent Parallel Processing\u003c\/strong\u003e\u003cbr\u003eEach module is equipped with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ededicated micro-controller\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto handle\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esignal conditioning and conversion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein parallel with the main CPU. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edistributed processing model\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that the system maintains\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econsistent 100ms update rates\u003c\/strong\u003e, regardless of the overall I\/O count, ensuring timely and accurate data processing even in large, complex systems.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module process Thermocouple or RTD signals?\u003c\/strong\u003e\u003cbr\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900A16-0301\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for high-level voltage and current signals. To process\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermocouple (TC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRTD\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignals, you would need a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUniversal Analog Input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuch as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900A01 series\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support HART communication?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900A16 series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprimarily handles high-level analog values and does not support\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHART protocol\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enatively. For full\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHART communication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCommand 3 and 48\u003c\/strong\u003e), the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControlEdge UIO\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Universal I\/O) module would typically be required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I monitor the module health?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900A16-0301\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etri-color \"Module Status\" LED\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon the front.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGreen\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicates the module is functioning properly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRed\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eflashing lights indicate specific\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efault codes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAmber\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignals indicate an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eI\/O override\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eforce in place\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 900A16-0301 \"hot-swappable\"?\u003c\/strong\u003e\u003cbr\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHC900 rack\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehot-swapping\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof I\/O modules. You can safely\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eremove and insert modules under power\u003c\/strong\u003e, and the controller will automatically sense the new module and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eauto-configure it\u003c\/strong\u003e, provided the model number matches the control strategy.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49011432980732,"sku":"900A16-0301","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/900A16-03012.jpg?v=1776847360","url":"https:\/\/www.electronicplc.com\/products\/900a16-0301-honeywell-16-channel-high-level-analog-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}