{"product_id":"900b08-0202-honeywell-8-channel-analog-output-module","title":"900B08-0202 Honeywell 8-Channel Analog Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 900B08-0202\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8-channel analog output module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControlEdge HC900\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem. It converts digital control signals from the HC900 CPU into precise analog current outputs, driving actuators such as valves, variable frequency drives (VFDs), and dampers. This module ensures stable process control and reliable performance in industrial automation environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e900B08-0202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Output (AO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Signal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-20 mA or 4-20 mA (software selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit minimum (high-resolution D\/A conversion)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 cm x 12.4 cm x 12.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation from backplane and between channel groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Control Modulation\u003c\/strong\u003e\u003cbr\u003eThe 900B08-0202 offers stable 4-20 mA signals for driving control elements with high repeatability, ensuring accurate response to PID algorithms and reducing process variability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFailsafe Configuration\u003c\/strong\u003e\u003cbr\u003eEach of the 8 channels can be programmed to hold the last value or transition to a safe output level during controller failure or communication loss, protecting critical equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Diagnostic Monitoring\u003c\/strong\u003e\u003cbr\u003eThe module continuously monitors output integrity, detecting faults like open circuits (e.g., broken field wires) and reporting them directly to the HC900 CPU for immediate action.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSlimline Design\u003c\/strong\u003e\u003cbr\u003eWith a compact 2.2 cm width, the module offers high I\/O density in the HC900 chassis, allowing engineers to deploy multiple analog output modules in a single rack for complex multi-loop control.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require an external power supply for the loops?\u003c\/strong\u003e\u003cbr\u003eThe 900B08-0202 typically draws power from the HC900 backplane. Ensure your power supply (e.g., 900P01) has sufficient capacity for all 8 channels at 20 mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I output voltage signals (0-10V) from this module?\u003c\/strong\u003e\u003cbr\u003eNo, the 900B08-0202 outputs only current signals (0-20 mA \/ 4-20 mA). For voltage outputs, use a different module designed for that purpose.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 900B08-0202 compatible with older HC900 racks?\u003c\/strong\u003e\u003cbr\u003eYes, this module is compatible across the standard HC900 hardware range. Ensure the correct model number and revision are configured in Hybrid Control Designer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the condition of the hardware?\u003c\/strong\u003e\u003cbr\u003eWe guarantee that the module is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, unused, and ships in its original Honeywell packaging to meet all manufacturer standards.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49011466666236,"sku":"900B08-0202","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/900U01-0100.jpg?v=1776847613","url":"https:\/\/www.electronicplc.com\/products\/900b08-0202-honeywell-8-channel-analog-output-module","provider":"Electronic PLC","version":"1.0","type":"link"}