{"product_id":"abb-advant-ac500-ax561-1tne968902r1301-analog-input-output-module","title":"ABB AX561 1TNE968902R1301 Analog Input\/Output Module","description":"\u003cp\u003eThe ABB AX561 (1TNE968902R1301) is a high-performance analog input\/output module designed for the AC500-eCo programmable automation controller platform. This compact S500-eCo series module provides versatile signal processing capabilities, featuring 4 individually configurable analog inputs and 2 configurable analog outputs, making it suitable for a wide range of industrial process control and monitoring tasks.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e4 Configurable Analog Inputs (AI0-AI3) and 2 Configurable Analog Outputs (AO0-AO1)\u003c\/li\u003e\n\u003cli\u003e12-bit resolution (13-bit for version E0 or later)\u003c\/li\u003e\n\u003cli\u003eComprehensive protection against reverse polarity, short circuits, and temporary overvoltage\u003c\/li\u003e\n\u003cli\u003eSupports multiple signal ranges: 0-10V, ±10V, 0-20mA, and 4-20mA\u003c\/li\u003e\n\u003cli\u003eCompact S500-eCo form factor optimized for DIN rail mounting\u003c\/li\u003e\n\u003cli\u003eIntegrated diagnostics and high-speed signal processing\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProcess Automation: Monitoring of temperature, pressure, flow, and level sensors in continuous manufacturing.\u003c\/li\u003e\n\u003cli\u003eBuilding Management: HVAC control, energy monitoring, and industrial lighting management.\u003c\/li\u003e\n\u003cli\u003eMachine Building: Integration with drives, valves, and actuators for custom machinery control.\u003c\/li\u003e\n\u003cli\u003eIndustrial Monitoring: Reliable acquisition of analog sensor data for safety and compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAX561 (1TNE968902R1301)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e4 (Configurable: Voltage\/Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e2 (Configurable: Voltage\/Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit (13-bit for E0+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003eVoltage: \u0026gt;1 MOhm; Current: ~250 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cable Length\u003c\/td\u003e\n\u003ctd\u003e10m (unshielded) \/ 100m (shielded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Off:\u003c\/strong\u003e Always disconnect the 24V DC power supply before installing or removing the module. Plugging or unplugging while powered can cause electrical damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Designed for standard DIN rail mounting within the AC500-eCo system. Ensure adequate ventilation space around the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect the 24V DC supply to terminals L+ and M. Use shielded, twisted-pair cabling for analog signals to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e For stable reference potential, interconnect the M terminal to the M\/ZP terminal on the CPU or communication interface module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e For cable runs exceeding 20 meters, shielded and grounded cables are mandatory to maintain signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the AX561 1TNE968902R1301?\u003c\/h3\u003e\u003cp\u003eThe ABB AX561 is a compact, S500-eCo series analog I\/O module used for process control and industrial automation within the AC500 PLC platform.\u003c\/p\u003e\u003ch3\u003eHow should I connect long cables?\u003c\/h3\u003e\u003cp\u003eAnalog signals are sensitive to electromagnetic interference. If your connection cable exceeds 20 meters, you must use a shielded and grounded cable to ensure accuracy.\u003c\/p\u003e\u003ch3\u003eCan I remove the module while the system is powered?\u003c\/h3\u003e\u003cp\u003eNo. It is strictly prohibited to plug, unplug, or connect signal terminals while the power is switched ON. Ensure all voltage sources are disconnected before servicing.\u003c\/p\u003e\u003ch3\u003eHow much power does the module consume?\u003c\/h3\u003e\u003cp\u003eThe module requires a 24V DC supply. Power consumption is approximately 5 mA per module added to your CPU or communication interface.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50994843189500,"sku":"AX561 1TNE968902R1301","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_2a5d6ce0-ec79-4b3a-a441-6c331bc48199.jpg?v=1787069508","url":"https:\/\/www.electronicplc.com\/products\/abb-advant-ac500-ax561-1tne968902r1301-analog-input-output-module","provider":"Electronic PLC","version":"1.0","type":"link"}