{"product_id":"abb-advant-s800-i-o-di880-3bse028586r1-digital-input-module","title":"ABB DI880 3BSE028586R1 Digital Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe ABB DI880 (3BSE028586R1) is a 16-channel, 24 V d.c. digital input module designed for the S800 I\/O system. It supports both single and redundant configurations, making it suitable for high-availability industrial control applications. Each input channel is equipped with current limiting, EMC protection, status indication LEDs, and optical isolation to ensure robust signal processing. The module also features advanced Sequence of Events (SOE) recording capabilities with 1 ms resolution, allowing for precise diagnostics and event tracking in critical systems.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 channels for 24 V d.c. inputs with current sinking.\u003c\/li\u003e\n\u003cli\u003eSupports single or redundant system configurations.\u003c\/li\u003e\n\u003cli\u003e1 group of 16 channels isolated from ground.\u003c\/li\u003e\n\u003cli\u003eIntegrated Sequence of Events (SOE) function with 1 ms resolution.\u003c\/li\u003e\n\u003cli\u003eCurrent-limited transducer power supply provided per input channel.\u003c\/li\u003e\n\u003cli\u003eAdvanced on-board diagnostics and input status LEDs.\u003c\/li\u003e\n\u003cli\u003eSupports hot-swapping for maintenance without system downtime.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSafety Instrumented Systems (SIS): Primary input for ESD and F\u0026amp;G applications.\u003c\/li\u003e\n\u003cli\u003eOil \u0026amp; Gas: Monitoring of critical valves, pressure switches, and level sensors.\u003c\/li\u003e\n\u003cli\u003ePower Generation: Turbine control and distribution protection.\u003c\/li\u003e\n\u003cli\u003eChemical \u0026amp; Petrochemical: Management of high-risk reactor inputs.\u003c\/li\u003e\n\u003cli\u003eMarine \u0026amp; Offshore: Certified for harsh maritime environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eDI880 3BSE028586R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Specification\u003c\/td\u003e\n\u003ctd\u003e24 V d.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18 to 30 V d.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e3.1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Times (Selectable)\u003c\/td\u003e\n\u003ctd\u003e0 to 127 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOE Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e2.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe DI880 must be installed with a compatible Module Termination Unit (MTU) such as the TU810, TU842, or TU843.\u003c\/li\u003e\n\u003cli\u003eMounting: Designed for horizontal or vertical DIN-rail installation. Ensure the locking mechanism is fully engaged for mechanical stability and proper electrical grounding.\u003c\/li\u003e\n\u003cli\u003eMechanical Keying: The module utilizes a keying code of FF to prevent incorrect module insertion into the MTU.\u003c\/li\u003e\n\u003cli\u003eHandling: Use standard ESD precautions when handling the module.\u003c\/li\u003e\n\u003cli\u003eHot Swapping: The module supports hot-swapping; however, always refer to the specific S800 I\/O system manual for safety procedures before removal or insertion under power.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\u003cp\u003eThe DI880 complies with EN50178, EN61131-2, and UL508 industrial standards. It is certified for use in SIL3 high-integrity applications.\u003c\/p\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003ch3\u003eDoes the DI880 3BSE028586R1 support event logging?\u003c\/h3\u003e\u003cp\u003eYes, the DI880 features Sequence of Events (SOE) functionality, collecting logical events with a resolution of 1 millisecond and a queue capacity of up to 512 x 16 events.\u003c\/p\u003e\u003ch3\u003eWhat is the voltage hold-up time?\u003c\/h3\u003e\u003cp\u003eIn the event of a mains blackout, the secondary output of the DI880 has a voltage hold-up time of approximately 46–47 ms.\u003c\/p\u003e\u003ch3\u003eIs the module compatible with redundant systems?\u003c\/h3\u003e\u003cp\u003eYes, the DI880 is designed to support both single and redundant configurations to meet high-availability requirements.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50915987063036,"sku":"DI880 3BSE028586R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_d43c4d6d-f746-4277-ab5e-fc5134030611.jpg?v=1785844528","url":"https:\/\/www.electronicplc.com\/products\/abb-advant-s800-i-o-di880-3bse028586r1-digital-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}