{"product_id":"abb-tps02-symphony-plus-turbine-protection-slave-unit","title":"ABB TPS02 Symphony Plus Turbine Protection Slave Unit","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTPS02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a turbine safety protection module for the ABB Symphony Plus Control System and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBailey Infi 90\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eautomation environments. It functions as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTurbine Protection Slave (TPS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule, providing high-speed monitoring and emergency protection logic for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esteam and gas turbine rotating equipment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe module continuously monitors critical safety parameters such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshaft speed and load balance\u003c\/strong\u003e, and can trigger emergency trip sequences to prevent mechanical damage or catastrophic overspeed events.\u003c\/p\u003e\n\u003cp\u003eIt communicates via the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eINFI-NET control network\u003c\/strong\u003e, allowing real-time transmission of protection and diagnostic data to master controllers and HMI systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTPS02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eSymphony Plus \/ Bailey Infi 90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\u003ctd\u003eOverspeed, trip logic, power imbalance detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Communication\u003c\/td\u003e\n\u003ctd\u003eINFI-NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Indicators\u003c\/td\u003e\n\u003ctd\u003eFront-panel multi-LED status display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Isolation\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 V protection rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStack-mount cabinet installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e17.8 × 5.1 × 33.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eCore Safety Functions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRapid overspeed trip execution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoad imbalance detection for sudden load rejection events\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous health status reporting to controller systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHardware-level shutdown capability via relay trip outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does TPS02 connect to emergency shutdown systems?\u003c\/strong\u003e\u003cbr\u003eIt typically drives\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehardwired relay outputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnected directly to turbine trip strings or hydraulic shutdown solenoids.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with legacy Infi 90 systems?\u003c\/strong\u003e\u003cbr\u003eYes, provided that Slave Bus parameters and mounting configurations are correctly set for TPS-series modules.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":48746767286524,"sku":"TPS02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/TPS021.jpg?v=1772090729","url":"https:\/\/www.electronicplc.com\/products\/abb-tps02-symphony-plus-turbine-protection-slave-unit","provider":"Electronic PLC","version":"1.0","type":"link"}