{"product_id":"aet4d-00-terminal-board-yokogawa","title":"AET4D-00 Terminal Board Yokogawa","description":"\u003cp\u003eConfigured for thermocouple signal integration, the \u003cstrong\u003eYokogawa AET4D-00\u003c\/strong\u003e (\u003cstrong\u003eAET4D\u003c\/strong\u003e Terminal Board) provides direct physical and electrical execution of multi-point temperature sensor signal transition to control system modules.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAET4D\u003c\/strong\u003e: Base series designation for thermocouple-specific analog terminal boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: Standard configuration code denoting universal signal path mapping for 16-channel thermocouple inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAET4D-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard terminal board footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot applicable (Passive component)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoints\u003c\/td\u003e\n\u003ctd\u003e16 points x 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eM4 screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e100 MΩ (at 500 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eThermocouple Signal Integrity and Compensation\u003c\/h3\u003e\n\u003cp\u003eThe AET4D-00 is engineered to maintain high-accuracy measurement for thermocouple sensors by minimizing potential thermal gradients across the board. The terminal design facilitates reliable connection for various thermocouple types, ensuring cold junction compensation (CJC) accuracy when integrated with the host I\/O modules. The board supports both single and redundant module configurations, providing high availability for critical process temperature monitoring loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the AET4D-00 be used with 4-20 mA current loops?\u003c\/p\u003e\n\u003cp\u003eA: The AET4D-00 is optimized specifically for thermocouple inputs. While the M4 terminals are physically capable of accepting current-loop wiring, the lack of integrated shunt resistors and the specific thermocouple-focused PCB trace geometry make it suboptimal for 4-20 mA HART loop protocol connectivity.\u003c\/p\u003e\n\u003cp\u003eQ: Is the board hot-swappable?\u003c\/p\u003e\n\u003cp\u003eA: No. The AET4D-00 is a passive field termination component. Maintenance, including thermocouple wire replacement, must be performed with the loop isolated and, where applicable, the controller power removed to prevent signal noise or damage to the I\/O module's input stages.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThermal Management: Install the terminal board in an area with minimal ambient temperature fluctuations. Rapid changes in environmental temperature near the board can introduce error in the thermocouple cold junction reference.\u003c\/li\u003e\n\u003cli\u003eTorque Specifications: Tighten M4 screw terminals to the manufacturer-recommended torque (1.2 Nm) to ensure consistent electrical contact. Over-tightening can strip the terminal threads, while under-tightening may lead to high-resistance connections and measurement drift.\u003c\/li\u003e\n\u003cli\u003eShielding: Ensure that all thermocouple extension cable shields are grounded at the system's instrument earth point to suppress electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eWiring Segregation: Maintain at least 300 mm of separation between thermocouple wiring and high-voltage AC power lines or VFD cabling to prevent inductive noise from impacting the millivolt-level temperature signals.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49265966874876,"sku":"AET4D-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AET4D-002.jpg?v=1783647839","url":"https:\/\/www.electronicplc.com\/products\/aet4d-00-terminal-board-yokogawa","provider":"Electronic PLC","version":"1.0","type":"link"}