{"product_id":"aip571-s1-yokogawa-analog-input-module","title":"AIP571\/S1 YOKOGAWA Analog Input Module","description":"\u003cp\u003eConfigured for precision signal acquisition in CENTUM CS and CENTUM VP control platforms, the \u003cstrong\u003eYOKOGAWA AIP571 S1\u003c\/strong\u003e (\u003cstrong\u003eAIP571\u003c\/strong\u003e Analog Input Module) provides direct physical and electrical execution of multi-variable sensor input processing.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe AIP571 S1 designates the standard hardware revision compatible with both CENTUM CS and CENTUM VP architectures. No further sub-variants or functional suffixes are documented for this specific hardware release in current operational manuals.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAIP571 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJanpan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003eVoltage, current, thermocouple, RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Instrumentation and Loop Integrity\u003c\/h3\u003e\n\u003cp\u003eThe AIP571 supports software-configurable input types on a per-channel basis, facilitating integration with diverse process sensors. The internal circuitry utilizes cold junction compensation (CJC) logic when thermocouple inputs are selected to minimize thermal drift errors. For 4-20 mA HART loop protocol integration, the module maintains strict impedance requirements to ensure the primary process variable remains within calibrated accuracy limits. Channel-to-channel isolation is implemented to prevent signal cross-talk during high-speed sampling intervals.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the AIP571 S1 be configured to mix thermocouple and RTD inputs on the same module?\u003c\/p\u003e\n\u003cp\u003eA: Yes, each of the 8 channels is independently programmable. Users must ensure that the appropriate hardware wiring, including the correct cold junction compensation terminal blocks, is utilized for thermocouple channels.\u003c\/p\u003e\n\u003cp\u003eQ: What is the primary communication method for transmitting data from this module to the controller?\u003c\/p\u003e\n\u003cp\u003eA: While the module samples analog inputs locally, data is relayed via the internal system backplane to the local station controller. The mention of Modbus RTU\/RS485 indicates the module's capability to interface with external auxiliary equipment or serial gateways as configured in the field control station.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module securely onto a standard 35 mm DIN rail in a non-hazardous, climate-controlled enclosure.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for all analog signals; ground the cable shield at the cabinet entry point only to prevent ground loop currents.\u003c\/li\u003e\n\u003cli\u003eEnsure the 24 VDC power supply is isolated from high-voltage AC circuits to minimize noise injection into the analog input circuitry.\u003c\/li\u003e\n\u003cli\u003eVerify that terminal connections for thermocouple inputs are tightened to the manufacturer's specified torque to ensure accurate cold junction temperature readings.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum clearance of 50 mm around the module housing to facilitate airflow and heat dissipation within the control cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49143188521212,"sku":"AIP571\/S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AIP571S12.jpg?v=1780019920","url":"https:\/\/www.electronicplc.com\/products\/aip571-s1-yokogawa-analog-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}