{"product_id":"allen-bradley-2711p-b12c6a2-panelview-plus-1250-hmi","title":"Allen-Bradley 2711P-B12C6A2 PanelView Plus 1250 Operator Terminal","description":"\u003cp\u003eThe 2711P-B12C6A2 is a robust industrial operator interface terminal from the Allen-Bradley PanelView Plus 1250 series. This HMI is engineered for demanding environments, providing real-time data visualization, system monitoring, and machine control by interfacing directly with industrial automation controllers. It is suitable for diverse applications, including petrochemical processing, power generation, automotive manufacturing, and municipal water management, offering clear process mimic visualization and stable control loop monitoring.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-input interface featuring an analog resistive touchscreen and 40 programmable function keys (F1–F20, K1–K20, numeric, and navigation) rated for 1 million actuations.\u003c\/li\u003e\n\u003cli\u003eIntegrated multi-protocol communication engine supporting Ethernet, Data Highway Plus (DH+), Remote I\/O (RIO), DH-485, and RS-232.\u003c\/li\u003e\n\u003cli\u003eRobust memory architecture with 128 MB RAM and 128 MB non-volatile Flash storage for application files and historical data.\u003c\/li\u003e\n\u003cli\u003eCompact Flash expansion slot for local memory expansion and system configuration backups.\u003c\/li\u003e\n\u003cli\u003eUSB peripheral ports for connecting external keyboards, mice, or mass storage devices.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis terminal is designed for integration into complex automation architectures where reliable operator feedback and control are critical. It is widely used in heavy industry for monitoring PLC-based processes, managing alarm logs, and providing a centralized point for machine interaction in distributed control systems.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-B12C6A2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e12.1 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eColor active matrix TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e800 x 600 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight Life\u003c\/td\u003e\n\u003ctd\u003e50,000 hours (CCFL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e160 VA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e128 MB RAM \/ 128 MB Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure adequate ventilation around the unit to maintain operating temperatures within the 0 to 55 deg C range.\u003c\/li\u003e\n\u003cli\u003eMount the terminal in a suitable NEMA\/IP-rated enclosure to protect against environmental contaminants.\u003c\/li\u003e\n\u003cli\u003eVerify that the AC power supply is within the specified 85–264 VAC range before applying power.\u003c\/li\u003e\n\u003cli\u003eUse shielded communication cables for Ethernet and serial connections to minimize EMI interference in industrial environments.\u003c\/li\u003e\n\u003cli\u003eAlways power down the system before inserting or removing Compact Flash cards or peripheral USB devices.\u003c\/li\u003e\n\u003cli\u003eEnsure a solid chassis ground connection to the panel to prevent electrical noise and ensure operator safety.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs this unit still in production?\u003c\/h3\u003e\u003cp\u003eNo, the 2711P-B12C6A2 is currently classified as a discontinued or obsolete product by the manufacturer. We provide these units as refurbished or surplus spare parts to support legacy system maintenance.\u003c\/p\u003e\u003ch3\u003eWhat communication protocols are supported?\u003c\/h3\u003e\u003cp\u003eThe unit supports a wide range of legacy and standard protocols including Ethernet, Data Highway Plus (DH+), Remote I\/O (RIO), DH-485, and RS-232, making it highly versatile for retrofitting older control systems.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":50995196133628,"sku":"2711P-B12C6A2","price":95.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_d2f4947d-38ef-4896-8d3e-196579413fcd.jpg?v=1787077534","url":"https:\/\/www.electronicplc.com\/products\/allen-bradley-2711p-b12c6a2-panelview-plus-1250-hmi","provider":"Electronic PLC","version":"1.0","type":"link"}