{"product_id":"alr121-s51-yokogawa-communication-module-new-original-stock","title":"ALR121-S51 YOKOGAWA Communication Module | New \u0026 Original Stock","description":"\u003cp\u003eConfigured for serial data orchestration within Yokogawa control networks, the \u003cstrong\u003eYOKOGAWA ALR121-S51\u003c\/strong\u003e (\u003cstrong\u003eALR121-S51\u003c\/strong\u003e Communication Module) provides direct physical signal transmission and protocol management between Field Control Units (FCUs) and third-party serial subsystems. This hardware component serves as the primary gateway utilized to execute data integration across distributed control platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eALR121\u003c\/strong\u003e: Base model identifier for the serial communication module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-S\u003c\/strong\u003e: Designates the standard version for serial interface support.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5\u003c\/strong\u003e: Specifies the communication variant (RS-232\/RS-422\/RS-485 configurable).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1\u003c\/strong\u003e: Indicates the standard conformance level for environmental integration within the FIO system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eALR121-S51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.2 cm x 12.4 cm x 12.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal DCS backplane power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eSerial communication interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Communication Integrity\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eALR121-S51\u003c\/strong\u003e manages the serial communication protocol to ensure deterministic data exchange between the main controller and field devices such as analyzers, transmitters, or PLCs. The module performs the electrical and logical conversion required for high-velocity signal transmission across the serial bus, minimizing communication latency. Proper configuration of the hardware ports allows for flexible integration into existing site-specific communication topologies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ALR121-S51 support simultaneous multi-protocol communication?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed to handle serial protocols as defined by the port configuration settings. While it supports multiple ports, ensure that the total communication load and parity\/baud rate settings align with the requirements of the connected field devices.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module compatible with hot-swapping procedures?\u003c\/p\u003e\n\u003cp\u003eA: The module supports hot-swapping if the system infrastructure and the specific FIO rack configuration allow for it. Always consult the system maintenance logs and verify cabinet power status before module extraction.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the rack slot is free of dust or metallic particulates before inserting the module to prevent backplane connector oxidation or short circuits.\u003c\/li\u003e\n\u003cli\u003eEnsure the module is seated fully against the backplane; use the provided retention screws to secure the faceplate and maintain a proper chassis ground.\u003c\/li\u003e\n\u003cli\u003eRoute serial cabling through dedicated cabinet ducts, maintaining a physical separation from high-current power or VFD motor leads to prevent electromagnetic noise injection into the communication signal.\u003c\/li\u003e\n\u003cli\u003ePerform a communication health check using the DCS engineering station software post-installation to verify the stability of the serial link and detect potential frame errors.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for RS-422\/RS-485 connections and ensure the shield drain wire is grounded at a single, appropriate reference point to eliminate ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49185091354876,"sku":"ALR121 -S51","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/ALR121-SE1.jpg?v=1780882795","url":"https:\/\/www.electronicplc.com\/products\/alr121-s51-yokogawa-communication-module-new-original-stock","provider":"Electronic PLC","version":"1.0","type":"link"}