{"product_id":"amm22-s3-yokogawa-analog-input-multiplexer-new-original-stock","title":"AMM22-S3 YOKOGAWA Analog Input Multiplexer New \u0026 Original Stock","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eYOKOGAWA AMM22-S3\u003c\/b\u003e, also cataloged as the \u003cb data-path-to-node=\"1\" data-index-in-node=\"45\"\u003eAMM22-S3\u003c\/b\u003e Analog Input Multiplexer Module, operates as a dedicated hardware component for high-speed signal aggregation within DCS network platforms.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"2\"\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"3\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,1,1,0\"\u003eAMM22-S3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,2,1,0\"\u003eYOKOGAWA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,3,1,0\"\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,4,1,0\"\u003e0.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,5,0,0\"\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,5,1,0\"\u003e12.7 cm x 2.5 cm x 20.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,6,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,6,1,0\"\u003e0 to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,7,1,0\"\u003e4.5 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,8,0,0\"\u003eChannel Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,8,1,0\"\u003eAnalog Multiplexer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eDCS Process Control and Signal Integrity\u003c\/h3\u003e\n\u003cp data-path-to-node=\"5\"\u003eThe module utilizes active channel-to-channel isolation to prevent potential common-mode noise propagation between disparate process loops. Integration with 4-20 mA HART loop protocol standards is supported, allowing for comprehensive diagnostic data transmission alongside primary process variables. The input stage incorporates precise cold junction compensation (CJC) logic, ensuring measurement stability across diverse thermal environments in field cabinets.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003eQ: Is this module compatible with existing system firmware versions for legacy DCS racks?\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003eA: The hardware is engineered for backward compatibility with standard system backplanes, but verification of the system database configuration is required to match the module I\/O scanning rate.\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003eQ: Can this module perform signal isolation for high-voltage differential inputs?\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003eA: The module is optimized for standard industrial analog levels; ensure external signal conditioners are utilized if input levels exceed the specified operating voltage range.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"10\"\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003eInspect the connector pins on the rear of the module for any debris or oxidation before seating it into the backplane slot.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003eSecure the front-panel mounting screws to the rack frame to ensure a rigid electrical connection and minimize vibration-induced contact resistance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003eGround the cable shields at the designated cabinet grounding terminal to mitigate electromagnetic interference (EMI) risks within the signal loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003eVerify the physical installation against the system wiring schematic to ensure correct signal mapping for the multiplexed channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49149504225532,"sku":"AMM22 S3","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AMM22_S31.jpg?v=1780277243","url":"https:\/\/www.electronicplc.com\/products\/amm22-s3-yokogawa-analog-input-multiplexer-new-original-stock","provider":"Electronic PLC","version":"1.0","type":"link"}