{"product_id":"asi133-h00-atsa3s-yokogawa-analog-input-module","title":"ASI133-H00\/ATSA3S Yokogawa Analog Input Module","description":"\u003cp\u003eConfigured for analog signal acquisition in Field Integrated Operation (FIO) platforms, the \u003cstrong\u003eYokogawa ASI133-H00\u003c\/strong\u003e (\u003cstrong\u003eASI133\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution. This 8-channel component serves as a primary interface for processing 4-20 mA current loops, ensuring data conversion and signal integrity across process control network environments.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eASI133-H00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.8 cm x 12.7 cm x 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C (Standard industrial range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSubject to system backplane supply requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Control and Signal Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module features dedicated channel-to-channel isolation, which is critical for preventing common-mode noise propagation and ground loop currents in complex instrumentation loops. This isolation architecture ensures that voltage transients or faults on a single field sensor circuit do not propagate to the common backplane or affect the measurement integrity of adjacent channels. The design adheres to FIO standard communication protocols, ensuring deterministic signal throughput and synchronization with the central controller within the DCS hierarchy.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ASI133-H00 support intrinsic safety (Ex i) for hazardous area connectivity?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed for compatibility with specific field integration environments. Verify the specific product revision and associated barrier requirements against the site's hazardous area classification documentation before field connection.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module be hot-swapped while the system is powered and operational?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the FIO series architecture supports module replacement during system operation. Ensure the module is fully unlatched and removed vertically to prevent backplane pin damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Seat the module into the designated FIO base unit. Ensure the mechanical alignment guides engage fully before securing the module with the integrated locking mechanism.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Terminate cable shields at the designated grounding busbar on the I\/O rack. Ensure the shield is continuous and maintained at the cabinet level to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Utilize twisted-pair shielded instrumentation cabling for all 4-20 mA loops. Adhere to specified torque settings for terminal connections to ensure long-term electrical contact stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Maintain adequate clearance above and below the module within the cabinet to facilitate passive convection cooling, ensuring the operating environment remains within the rated temperature limits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49239991288060,"sku":"ASI133-H00\/ATSA3S","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/ASI133-H00.jpg?v=1780971136","url":"https:\/\/www.electronicplc.com\/products\/asi133-h00-atsa3s-yokogawa-analog-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}