{"product_id":"asi133-s50-sa3s0-analog-input-module-yokogawa","title":"ASI133-S50\/SA3S0 Analog Input Module Yokogawa","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ASI133-S50\/SA3S0\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eASI133-S50\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for 8-channel 4-20 mA current signal acquisition within Yokogawa DCS control networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eASI133-S50\/SA3S0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Isolation\u003c\/td\u003e\n\u003ctd\u003eGalvanically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Signal Conditioning \u0026amp; Isolation\u003c\/h3\u003e\n\u003cp\u003eThis module ensures integrity in signal acquisition through dedicated channel-to-channel isolation. By maintaining galvanic separation between the field-side current loops and the internal DCS backplane, the unit suppresses common-mode noise and prevents ground potential interference. This architectural approach is mandatory for maintaining signal accuracy when interfacing with multiple field transmitters that may share common supply rails or reference points in expansive process environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ASI133-S50 support HART communication transparency for connected field devices?\u003c\/p\u003e\n\u003cp\u003eA: The module is optimized for standard 4-20 mA current signal processing. Users must verify the specific hardware revision for HART protocol signal transparency if digital communication overlay is required on the analog loop.\u003c\/p\u003e\n\u003cp\u003eQ: What is the recommended termination method for the analog signal wires?\u003c\/p\u003e\n\u003cp\u003eA: Use the specified pressure clamp terminal blocks, such as the ATSA3S. Ensure that each conductor is stripped to the manufacturer's recommended length to ensure full engagement within the clamp without exposed copper strands.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Protocol:\u003c\/strong\u003e Secure the module onto the dedicated system mounting rail. Ensure the module is seated fully into the backplane connector to establish both power and communication links.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Terminate cable shields at the designated cabinet grounding bus. Maintain consistent shielding practice across all 8 channels to prevent inductive coupling from adjacent high-voltage power cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Loop Integrity:\u003c\/strong\u003e Verify the loop resistance of field wiring prior to final connection. Ensure that the 4-20 mA signal remains within the operational range defined by the DCS input impedance to prevent signal clipping or measurement errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Sealing:\u003c\/strong\u003e If installed in hazardous or high-particulate areas, ensure the cabinet integrity is maintained to prevent the accumulation of conductive dust on the terminal block assembly, which could degrade input isolation performance over time.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49239922082044,"sku":"ASI133-S50\/SA3S0","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/ASI133-H00.jpg?v=1780971136","url":"https:\/\/www.electronicplc.com\/products\/asi133-s50-sa3s0-analog-input-module-yokogawa","provider":"Electronic PLC","version":"1.0","type":"link"}