{"product_id":"atsr3d-analog-rtd-pot-module-yokogawa","title":"ATSR3D Analog RTD\/POT Module YOKOGAWA","description":"\u003cp\u003eConfigured for high-precision temperature and resistance acquisition, the \u003cstrong\u003eYOKOGAWA ATSR3D-0\u003c\/strong\u003e (\u003cstrong\u003eATSR3D-0\u003c\/strong\u003e Analog RTD\/POT Module) provides direct physical execution of analog signal conversion within control networks. The module serves as a primary interface for Resistance Temperature Detectors (RTDs) and potentiometers, facilitating dual-redundant analog signal output for critical process monitoring and control loops.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATSR3D\u003c\/strong\u003e: Base model designation for the analog RTD\/POT input module with dual-redundant output capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-0\u003c\/strong\u003e: Standard hardware revision level for base functional configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eATSR3D-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003ejapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact industrial footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSubject to loop load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eRTD (Pt100, Pt500) \/ Potentiometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDual-redundant linear analog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Cold Junction Compensation\u003c\/h3\u003e\n\u003cp\u003eThe ATSR3D-0 architecture utilizes internal circuitry to ensure signal linearity between resistance inputs and the corresponding voltage outputs. While the module is optimized for RTD and potentiometer interfacing, it maintains consistent signal fidelity across both channels through channel-to-channel isolation techniques. This isolation prevents ground loops and electrical interference from influencing measurement accuracy in multi-sensor installations. The module design is calibrated to provide a stable 4-20 mA HART loop protocol compliant output, ensuring compatibility with standard DCS and PLC input cards without the requirement for dedicated cold junction compensation (CJC) circuits typically found in thermocouple modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the ATSR3D-0 operate with a single output if the redundant channel fails?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module is engineered for dual-redundant output execution; if a fault is detected in one output channel, the secondary channel maintains signal transmission to ensure the control system retains process visibility.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module field-configurable for different RTD types?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports various RTD configurations; however, configuration parameters must be verified through the hardware interface or software settings to match the specific resistance-temperature curve of the connected sensor.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure all power to the signal loop is isolated before connecting RTD or potentiometer inputs to the module terminals.\u003c\/li\u003e\n\u003cli\u003eVerify that the sensor wiring resistance is within the allowable limits for the specific RTD type to prevent measurement drift.\u003c\/li\u003e\n\u003cli\u003eInstall the module in a low-vibration area of the control cabinet, ensuring adequate clearance for thermal dissipation.\u003c\/li\u003e\n\u003cli\u003eUtilize shielded twisted-pair cabling for all sensor inputs to mitigate electromagnetic noise, bonding the shield to a clean instrument ground at the cabinet entry point.\u003c\/li\u003e\n\u003cli\u003ePerform a multi-point calibration check after installation to confirm that the resistance-to-output linearity matches the process requirements.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":50115217326332,"sku":"ATSR3D","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AAB841-S03M4A00.jpg?v=1784165734","url":"https:\/\/www.electronicplc.com\/products\/atsr3d-analog-rtd-pot-module-yokogawa","provider":"Electronic PLC","version":"1.0","type":"link"}