{"product_id":"bachmann-m1-system-bs209-9-slot-backplane-base-plate","title":"Bachmann M1 System BS209 9-Slot Backplane Base Plate","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBS209\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9-slot high-density backplane\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the Bachmann M1 automation system, providing both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emechanical support and high-speed electrical interconnectivity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor CPUs, I\/O modules, and communication cards. Its robust\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eparallel bus architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures deterministic data exchange, while the passive design eliminates active failure points. Ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewind turbines, maritime, and industrial applications\u003c\/strong\u003e, the BS209 supports large-scale, modular M1 systems with high reliability and mechanical stability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBS209\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePassive Backplane \/ Base Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlot Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 Module Slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3 cm x 5.5 cm x 11.9 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail or mounting plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-speed parallel backplane with EMI shielding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Reliability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePassive design – no active electronics to fail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal or vertical (ensure module heat clearance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications \u0026amp; Use Cases\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCentral foundation for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density M1 systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e7 expansion modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein addition to CPU and power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial environments with high vibration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(e.g., wind turbines, marine engine rooms).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Hardware Comparison\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOffers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigher slot density\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethan BS205 (5-slot) and BS207 (7-slot) base racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintains\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeterministic, low-latency parallel bus communication\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecomplex automation projects\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecombining multiple fieldbus interfaces and local analog\/digital I\/O.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Do I need to terminate the bus on the BS209?\u003c\/strong\u003e\u003cbr\u003eA: No. The M1 system backplane automatically handles signal termination once modules are installed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I mount the BS209 horizontally or vertically?\u003c\/strong\u003e\u003cbr\u003eA: Yes, both orientations are supported. Ensure adequate clearance for heat dissipation from active modules.\u003c\/p\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":48746768236796,"sku":"BS209","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/BS2092_715d3236-97f4-46dc-9e23-cc81080988ae.jpg?v=1770361973","url":"https:\/\/www.electronicplc.com\/products\/bachmann-m1-system-bs209-9-slot-backplane-base-plate","provider":"Electronic PLC","version":"1.0","type":"link"}