{"product_id":"bently-nevada-106m1081-01-universal-ac-power-input-module","title":"Bently Nevada 106M1081-01 Universal AC Power Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e106M1081-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUniversal AC Power Input Module (PIM)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500 Machinery Protection System\u003c\/strong\u003e. Serving as the interface between incoming AC power and the Universal AC Power Supply, it ensures stable voltage conditioning and delivery to the 3500 rack’s monitoring modules. This module is specifically intended for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUniversal AC architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand is not compatible with legacy High Voltage or Low Voltage AC units.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e106M1081-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eUniversal AC Power Input Module (PIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eUniversal AC Power Supply (Non-legacy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47–63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e3 cm x 13 cm x 13 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOperational Overview\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal AC Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAutomatically adapts to varying AC voltages without manual range switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRack Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to work exclusively with Universal AC Power Supply modules within the 3500 series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Conditioning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsures stable and reliable power delivery to critical machinery monitoring modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Compatible with Legacy Units:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrevents accidental mixing with older high- or low-voltage AC units, which could damage the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInput conditioning for modern 3500 racks using Universal AC Power Supplies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsuring reliable AC power delivery to machinery protection modules in turbines, compressors, and industrial pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandardizing power input across facilities with varying voltage levels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the 106M1081-01 not compatible with legacy High\/Low Voltage AC units?\u003c\/strong\u003e\u003cbr\u003eUniversal architecture uses different internal signal conditioning and pin-out configurations. Mixing with legacy units can cause power faults or failure to initialize the rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the input frequency drops below 47 Hz?\u003c\/strong\u003e\u003cbr\u003eVoltage regulation may become inconsistent, potentially triggering \"Power Input Fault\" alarms on the Rack Interface Module (RIM).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can I identify a Universal versus Legacy system?\u003c\/strong\u003e\u003cbr\u003eCheck the front-panel labels: Universal components indicate “Universal AC” or match current 3500 product numbers. Legacy units typically show specific nominal voltages, like “110 VAC” or “220 VAC.”\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746723442940,"sku":"3500\/15 106M1081-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/350015_106M1081-012.jpg?v=1773387058","url":"https:\/\/www.electronicplc.com\/products\/bently-nevada-106m1081-01-universal-ac-power-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}