{"product_id":"bently-nevada-3300-series-3300-10-02-02-00-ac-power-supply-module","title":"Bently Nevada 3300 Series 3300\/10-02-02-00 AC Power Supply Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/10-02-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efoundational power conversion module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 Machinery Protection System\u003c\/strong\u003e. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-reliability power supply\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to occupy the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efar-left position\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 rack\u003c\/strong\u003e, converting primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efacility AC power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einto the regulated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDC voltages\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequired by the backplane to power monitoring cards and proximity transducers.\u003c\/p\u003e\n\u003cp\u003eBuilt for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emission-critical industrial environments\u003c\/strong\u003e, the 3300\/10-02-02-00 incorporates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eadvanced line filtering\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esurge suppression\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto protect sensitive monitoring electronics from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egrid fluctuations\u003c\/strong\u003e. This configuration is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-voltage AC inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(220 VAC) and includes an integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePower Input Module (PIM)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat provides a secure, fused connection point for field wiring, ensuring that power transients do not compromise system integrity or signal reliability.\u003c\/p\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/10-02-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Power Supply with Power Input Module (PIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e175 to 250 VAC (Nominal 220 VAC), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRegulated ±24 VDC and +5 VDC (System Backplane Voltages)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSufficient to drive a fully populated 3300 rack (up to 12 monitoring modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Connector Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard AC Power Input Module with Fuse Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Non-Hazardous \/ CSA\/NRTL\/C (General Purpose)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOver-voltage protection, short-circuit current limiting, and EMI filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between primary AC input and DC secondary outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C to +65°C (-22°F to +149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/10-02-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the primary power source for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 racks\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eused in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower plants\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoil refineries\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egas processing facilities\u003c\/strong\u003e. It is essential for any facility using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e220V\/240V mains power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto energize their\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evibration\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethrust\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etemperature monitoring systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003ch4\u003eCan this module be replaced while the rack is powered?\u003c\/h4\u003e\n\u003cp\u003eAlthough the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 system\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis robust, it is highly recommended to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ede-energize\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethe primary AC source before removing or installing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/10-02-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower supply to prevent arcing and ensure technician safety.\u003c\/p\u003e\n\u003ch4\u003eDoes this part include the rear Power Input Module (PIM)?\u003c\/h4\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"-02\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoption in the configuration code specifies the inclusion of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePower Input Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e175–250 VAC range\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003eWhat should I check if the 'Supply OK' LED is off?\u003c\/h4\u003e\n\u003cp\u003eFirst, verify the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprimary AC input\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eat the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePIM terminals\u003c\/strong\u003e. If power is present, check the user-replaceable fuse located on the PIM. If the fuse is intact and the LED remains off, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einternal power conversion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehas likely failed.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746762633468,"sku":"3300\/10-02-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330010-02-02-001.jpg?v=1772175918","url":"https:\/\/www.electronicplc.com\/products\/bently-nevada-3300-series-3300-10-02-02-00-ac-power-supply-module","provider":"Electronic PLC","version":"1.0","type":"link"}