{"product_id":"cc-paih02-51405039-175-hart-analog-input-module-honeywell","title":"CC-PAIH02 51405039-175 HART Analog Input Module Honeywell","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-PAIH02 (51405039-175) is a HART-enabled High-Level Analog Input (HLAI) module for the Experion PKS Series C platform. It acquires 16 channels of 4–20 mA signals from field transmitters while simultaneously processing HART digital communication over the same wiring.\u003c\/p\u003e\n\u003cp\u003eIntegrated with the C300 controller, it provides accurate process variable measurement along with real-time instrument diagnostics. Supplied as 100% brand new, original factory equipment, it ensures reliable performance and seamless system integration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eCC-PAIH02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51405039-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Level Analog Input (HLAI) with HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA, 1–5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit A\/D conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e60 W (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating\u003c\/td\u003e\n\u003ctd\u003eConformal coated (-175 revision)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHART Communication Support\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Enables remote diagnostics, calibration, and asset management via digital HART data\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Signal Accuracy\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– 16-bit conversion ensures precise process measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNoise Immunity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Differential inputs and shielding reduce EMI and ground loop effects\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Cabinet Design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Vertical form factor maximizes space and supports passive cooling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHarsh Environment Protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Conformal coating resists moisture and corrosive gases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Capability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Replace modules without shutting down the system or rewiring field connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Ready\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Supports 1:1 redundant configurations with compatible IOTA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support redundancy?\u003c\/strong\u003e\u003cbr\u003eYes, when installed in a redundancy-capable IOTA with a paired module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it power 2-wire transmitters?\u003c\/strong\u003e\u003cbr\u003eYes, loop power is provided through the IOTA within the Series C system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between 51405038 and 51405039 series?\u003c\/strong\u003e\u003cbr\u003eThe 51405039 series reflects a revised hardware version with updated internal components while maintaining functional compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does it handle faults?\u003c\/strong\u003e\u003cbr\u003eThe module continuously monitors each channel and reports open circuits, out-of-range signals, or device issues to the Experion HMI for diagnostics.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48912635265276,"sku":"CC-PAIH02 51405039-175","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CC-PAIH02_51405038-375.jpg?v=1775112508","url":"https:\/\/www.electronicplc.com\/products\/cc-paih02-51405039-175-hart-analog-input-module-honeywell","provider":"Electronic PLC","version":"1.0","type":"link"}