{"product_id":"cc-pfb801-honeywell-fieldbus-interface-module","title":"CC-PFB801 Honeywell Fieldbus Interface Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell CC-PFB801\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-capacity\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFOUNDATION Fieldbus (FF) H1 interface module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003especifically designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol platform. This module acts as the digital bridge between the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eC300 controller\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand smart field instrumentation, facilitating the exchange of multi-variable process data and advanced device diagnostics. By supporting the 31.25 kbit\/s H1 protocol, the CC-PFB801 enables\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControl in the Field (CIF)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand comprehensive asset management directly from the DCS console. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring the highest level of network reliability for your smart field segments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCC-PFB801\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFOUNDATION Fieldbus H1 Interface (Enhanced Density)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFOUNDATION Fieldbus H1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.7 cm x 12.7 cm x 12.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlatform Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series C \/ C300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries C Fieldbus IOTA (Input Output Termination Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003ch4\u003eEnhanced Segment Management\u003c\/h4\u003e\n\u003cp\u003eThe CC-PFB801 manages high-density Fieldbus segments, allowing for more smart devices per I\/O rack while maintaining deterministic communication for critical control loops.\u003c\/p\u003e\n\u003ch4\u003eSmart Asset Transparency\u003c\/h4\u003e\n\u003cp\u003eThis module extracts secondary variables and status alerts from field transmitters and valve positioners, enabling predictive maintenance through Honeywell’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAsset Management System (AMS)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003eRobust Signal Isolation\u003c\/h4\u003e\n\u003cp\u003eIntegrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egalvanic isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotects the C300 controller and the FTE network from electrical surges, noise, or short circuits occurring on the long-distance Fieldbus home-run cables.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003ch4\u003eWhat is the primary difference between the CC-PFB401 and the CC-PFB801?\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PFB801\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis typically utilized in configurations requiring higher segment density or specific Series C hardware builds. It features a larger physical footprint (12.7 cm cubic) to accommodate enhanced signal processing hardware.\u003c\/p\u003e\n\u003ch4\u003eDoes this module provide power to the FF H1 segment?\u003c\/h4\u003e\n\u003cp\u003eNo, the CC-PFB801 handles\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edata communication only\u003c\/strong\u003e. You must use an external, conditioned\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFieldbus Power Supply (FPS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto energize the H1 segment and its connected devices.\u003c\/p\u003e\n\u003ch4\u003eIs the CC-PFB801 hot-swappable in a redundant setup?\u003c\/h4\u003e\n\u003cp\u003eYes, in a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant IOTA configuration\u003c\/strong\u003e, you can replace a failed CC-PFB801 while the secondary module maintains uninterrupted communication with the field instruments.\u003c\/p\u003e\n\u003ch4\u003eHow do I verify the module is \"Brand New\"?\u003c\/h4\u003e\n\u003cp\u003eWe ship all\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PFB801\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoriginal Honeywell factory packaging\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith intact security seals, complete with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecertificate of origin\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure the hardware has never been previously installed.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48901025792252,"sku":"CC-PFB801","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CC-PFB801.jpg?v=1774854173","url":"https:\/\/www.electronicplc.com\/products\/cc-pfb801-honeywell-fieldbus-interface-module","provider":"Electronic PLC","version":"1.0","type":"link"}