{"product_id":"cc-ppix01-honeywell-pulse-input-module","title":"CC-PPIX01 Honeywell Pulse Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell CC-PPIX01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-speed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePulse Input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems. It processes high-frequency signals from devices like flow meters and tachometers, converting pulses into units like\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eflow rate\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etotalized volume\u003c\/strong\u003e, or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003espeed\u003c\/strong\u003e. This ensures accurate real-time data for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eC300 controller\u003c\/strong\u003e. The unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor reliable performance.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCC-PPIX01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePulse Input (PI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-speed Differential or Single-ended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 100 kHz (application dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDry contact, Open collector, or Voltage pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlatform Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Series C Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries C IOTA (Input Output Termination Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Pulse Processing\u003c\/strong\u003e: Handles fast pulses for accurate flow and speed measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Totalization\u003c\/strong\u003e: Local pulse accumulation for reliable totals, even during communication interruptions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustable Thresholds\u003c\/strong\u003e: Software-configured levels to filter noise and signal distortion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e: Protects electronics from voltage spikes and interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Capability\u003c\/strong\u003e: Replace modules without interrupting operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan it power field sensors?\u003c\/strong\u003e\u003cbr\u003eNo, external power supply required for active sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support frequency-to-analog conversion?\u003c\/strong\u003e\u003cbr\u003eYes, frequency can be mapped to process variables like\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLiters\/Minute\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRPM\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is it different from a standard DI module?\u003c\/strong\u003e\u003cbr\u003eIt tracks pulses at much higher speeds (up to 100 kHz), ensuring zero data loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow to ensure clean pulse signals?\u003c\/strong\u003e\u003cbr\u003eUse\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshielded twisted-pair cabling\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand proper grounding to reduce interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48901026545916,"sku":"CC-PPIX01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CC-PAIX021.jpg?v=1774941666","url":"https:\/\/www.electronicplc.com\/products\/cc-ppix01-honeywell-pulse-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}