{"product_id":"cc-taim01-51305959-175-honeywell-low-level-analog-input-multiplexer-module","title":"CC-TAIM01 51305959-175 Honeywell Low-Level Analog Input Multiplexer Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell CC-TAIM01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51305959-175\u003c\/strong\u003e) is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density, low-level analog input multiplexer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(MUX) designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems. This module consolidates signals from a wide range of low-voltage field sensors, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermocouples\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(TC) and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRTDs\u003c\/strong\u003e, into the controller environment. With 64 isolated channels, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TAIM01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ereduces the required hardware footprint for large-scale temperature and pressure monitoring networks. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor reliable signal integrity in industrial settings.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCC-TAIM01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51305959-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-level Analog Signals (TC, RTD, mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScan Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 Channels per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull Channel-to-Channel and Channel-to-System isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0 cm x 31.3 cm x 27.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.56 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlatform Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series C \/ C300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries C IOTA (Input Output Termination Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMassive Channel Density\u003c\/strong\u003e: Monitor up to 64 sensors using a single I\/O slot, reducing module count, cables, and termination assemblies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Signal Isolation\u003c\/strong\u003e: Prevents ground loops and limits sensor faults from propagating, ensuring high system availability in industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Signal Scanning\u003c\/strong\u003e: Scans 64 channels per second, providing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-frequency data\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor accurate temperature and process monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElimination of EMI Interference\u003c\/strong\u003e: Advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enoise rejection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecircuitry ensures accurate data collection from low-level signals, even in electromagnetically noisy environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Maintenance Design\u003c\/strong\u003e: Slim\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3 cm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewidth optimizes cabinet space, while redundant diagnostic LEDs allow quick verification of module health.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003ch4\u003eWhat types of low-level sensors does the CC-TAIM01 support?\u003c\/h4\u003e\n\u003cp\u003eThe module supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emV signals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermocouples\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRTDs\u003c\/strong\u003e. The specific sensor type must be configured within\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS software\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003eDoes the CC-TAIM01 require a specialized IOTA?\u003c\/h4\u003e\n\u003cp\u003eYes, it requires a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density Series C IOTA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto support its 64-channel count. Ensure your field wiring plan accounts for the full connectivity.\u003c\/p\u003e\n\u003ch4\u003eHow does this module handle cold-junction compensation (CJC)?\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TAIM01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eworks with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIOTA\u003c\/strong\u003e, which houses the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCJC sensors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto compensate for ambient temperature variations.\u003c\/p\u003e\n\u003ch4\u003eIs the 51305959-175 version backward compatible?\u003c\/h4\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-175 version\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis fully compatible with existing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series C systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand offers improved thermal resilience over older\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-100 series modules\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48901036081404,"sku":"CC-TAIM01 51305959-175","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CC-TAIM01_51305959-1752.jpg?v=1774854174","url":"https:\/\/www.electronicplc.com\/products\/cc-taim01-51305959-175-honeywell-low-level-analog-input-multiplexer-module","provider":"Electronic PLC","version":"1.0","type":"link"}