{"product_id":"cc-tdi230-honeywell-digital-input-module","title":"CC-TDI230 Honeywell Digital Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell CC-TDI230\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates as a high-reliability Digital Input Termination Assembly (IOTA) within the Experion PKS Series C architecture. This module specializes in detecting discrete signals from 220\/240 VAC field devices, such as industrial limit switches and power status contacts. It supports redundant configurations, providing a fault-tolerant interface that ensures continuous process monitoring even if a single component fails. This unit is supplied as 100% brand new and original factory hardware.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCC-TDI230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180–264 VAC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47–63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSense Current (ON)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 1.11 mA RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSense Current (OFF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 0.32 mA RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePick-Up Voltage (Min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180 VAC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrop-Out Voltage (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 VAC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Delay (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports redundant I\/O module pairs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Voltage Signal Directness\u003c\/strong\u003e: The CC-TDI230 accepts 240 VAC inputs directly from field devices, eliminating the need for external interposing relays and simplifying cabinet wiring and design.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFault-Tolerant Architecture\u003c\/strong\u003e: Supports redundant module pairing, allowing a secondary module to maintain signal acquisition if the primary module fails, ensuring uninterrupted monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWide Voltage Tolerance\u003c\/strong\u003e: Operates reliably across 180–264 VAC, accommodating fluctuations in industrial power systems and preventing false alarms during voltage instability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Signal Response\u003c\/strong\u003e: With a maximum input delay of 25 ms, the module delivers fast and accurate discrete signal updates suitable for safety interlocks and sequence-of-events (SOE) applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003ch4\u003eCan this module function in a non-redundant (simplex) setup?\u003c\/h4\u003e\n\u003cp\u003eYes, although the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TDI230\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports redundancy, it can also be configured for simplex operation depending on system design and Experion PKS channel requirements.\u003c\/p\u003e\n\u003ch4\u003eHow does the module distinguish between an 'OFF' state and a low-voltage leakage?\u003c\/h4\u003e\n\u003cp\u003eThe module uses defined sense current thresholds. Signals below 0.32 mA are interpreted as OFF, while currents above 1.11 mA are recognized as ON, effectively filtering out leakage currents and electrical noise.\u003c\/p\u003e\n\u003ch4\u003eWhat is the significance of the 180 VAC pick-up voltage?\u003c\/h4\u003e\n\u003cp\u003eThe pick-up threshold ensures that the input is only registered as ON when sufficient voltage is present to reliably drive the field device, improving accuracy and preventing false state detection.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48901050695932,"sku":"CC-TDI230","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CC-TDI2301.jpg?v=1774854174","url":"https:\/\/www.electronicplc.com\/products\/cc-tdi230-honeywell-digital-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}