{"product_id":"contact-output-module-yokogawa-csl-adm51c-2","title":"Contact Output Module Yokogawa CSL\/ADM51C-2","description":"\u003cp\u003eConfigured for high-density discrete command execution in CENTUM CS 1000 and CS 3000 control platforms, the \u003cstrong\u003eYokogawa CSL\/ADM51C-2\u003c\/strong\u003e (\u003cstrong\u003eADM51C\u003c\/strong\u003e Contact Output Module) provides direct electrical execution for 16 or 32 point transistor contact outputs. This module supports diverse operational modes including status, pulse-type, and time-proportional output, ensuring precise control over industrial relays and actuators.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSL\/ADM51C\u003c\/td\u003e\n\u003ctd\u003eBase Contact Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-2\u003c\/td\u003e\n\u003ctd\u003eStandard configuration variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCSL\/ADM51C-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DCS module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e600 mA (5.0 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e16 or 32 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 V DC, 100 mA (Resistive\/Inductive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Resolution\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Instrumentation and Output Flexibility\u003c\/h3\u003e\n\u003cp\u003eThe ADM51C-2 architecture is engineered to provide versatile discrete signal control with programmable pulse width settings ranging from 0.1 to 7200 seconds. By offering status output, one-shot pulse modes, and time-proportional ON\/OFF functionality, the module effectively manages complex load switching requirements within DCS loops. The transistor contact outputs are rated for 30 V DC at 100 mA, allowing for robust interfacing with external auxiliary relays or solenoid valves while maintaining system-level signal integrity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the pulse width setting be adjusted dynamically during active process execution?\u003c\/p\u003e\n\u003cp\u003eA: Pulse width settings are configured within the system software; modifications should follow standard engineering station protocols to ensure consistent loop performance.\u003c\/p\u003e\n\u003cp\u003eQ: Is the contact rating for inductive loads significantly lower than for resistive loads?\u003c\/p\u003e\n\u003cp\u003eA: The module is rated for 100 mA for both resistive and inductive loads; however, when switching highly inductive devices, the use of external flyback diodes is recommended to suppress back-EMF.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module securely in the designated I\/O nest, ensuring the backplane connector is fully seated to prevent power supply instability.\u003c\/li\u003e\n\u003cli\u003eVerify that field loads are fused appropriately for the 100 mA maximum contact rating to prevent catastrophic damage to the module transistors.\u003c\/li\u003e\n\u003cli\u003eMaintain physical separation between discrete output wiring and high-voltage power lines to minimize induced electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eEnsure that all common terminal returns are correctly bonded to the system signal ground to preserve the electrical isolation of the transistor outputs.\u003c\/li\u003e\n\u003cli\u003ePeriodically inspect terminal connections for mechanical security, as industrial vibration can degrade the quality of electrical contact over time.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":50203664646396,"sku":"CSL\/ADM51C-2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/ADM51C.jpg?v=1781575117","url":"https:\/\/www.electronicplc.com\/products\/contact-output-module-yokogawa-csl-adm51c-2","provider":"Electronic PLC","version":"1.0","type":"link"}