{"product_id":"control-firewall-module-cc-pcf901-51405047-175-honeywell","title":"Control Firewall Module CC-PCF901 51405047-175 Honeywell","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-PCF901 (Part Number: 51405047-175) is a dedicated security appliance within the Experion Series C I\/O Mark II architecture. It functions as a control firewall module, providing network segmentation, traffic filtering, and access control to protect C300 controllers from unauthorized access and network disturbances. Designed for mission-critical Distributed Control System (DCS) environments, it ensures secure and deterministic operation within the Fault Tolerant Ethernet (FTE) network. This unit is supplied as 100% Brand New Original equipment.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eCC-PCF901\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51405047-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eExperion Series C I\/O Mark II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e8 × 10\/100 Mbps Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUplink Ports\u003c\/td\u003e\n\u003ctd\u003e1 × Dedicated Uplink Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity Functions\u003c\/td\u003e\n\u003ctd\u003eFirewall Filtering, Access Control, Segmentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e85 × 50 × 22 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eReal-time Traffic Analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Network Segmentation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIsolates I\/O networks from supervisory FTE networks, preventing fault propagation and broadcast storms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Traffic Filtering:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHardware-level packet inspection prioritizes critical control traffic while blocking unauthorized or non-essential communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact High-Density Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated 8-port switch reduces the need for external networking hardware and simplifies cabinet wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGranular Access Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnforces strict communication policies to strengthen cybersecurity and protect control assets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the CC-PCF901 require the CC-TCF-901 termination assembly?\u003c\/strong\u003e\u003cbr\u003eYes, it must be installed on a compatible IOTA such as the CC-TCF-901 for proper connectivity and operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does it support Fault Tolerant Ethernet (FTE)?\u003c\/strong\u003e\u003cbr\u003eIt manages dual-path communications while applying filtering to both network paths, maintaining redundancy and security simultaneously.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan firewall rules be configured manually?\u003c\/strong\u003e\u003cbr\u003eYes, configuration is managed through Honeywell Experion PKS tools (e.g., Configuration Studio), aligning with system-level policies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the module fails?\u003c\/strong\u003e\u003cbr\u003eIn redundant setups, a secondary unit takes over automatically. In non-redundant configurations, system behavior depends on the configured fail-safe strategy (fail-open or fail-closed).\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48949974434044,"sku":"CC-PCF901 51405047-175","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CC-PCF901_51405047-175.jpg?v=1775720203","url":"https:\/\/www.electronicplc.com\/products\/control-firewall-module-cc-pcf901-51405047-175-honeywell","provider":"Electronic PLC","version":"1.0","type":"link"}