{"product_id":"control-firewall-module-cc-pcf901-honeywell","title":"Control Firewall Module CC-PCF901 Honeywell","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PCF901\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance network security module within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Experion PKS Series C architecture\u003c\/strong\u003e. It functions as a dedicated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControl Firewall (CF9)\u003c\/strong\u003e, providing a hardened security layer that protects\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eC300 controllers\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom unauthorized network traffic and Ethernet congestion.\u003c\/p\u003e\n\u003cp\u003eBy isolating the control network from supervisory systems, the CC-PCF901 ensures deterministic communication and prevents disruptions caused by network storms, broadcast floods, or malicious traffic. It is specifically designed to prioritize safety-critical control data while filtering out non-essential packets at the hardware level.\u003c\/p\u003e\n\u003cp\u003eThe module serves as the primary interface for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFault Tolerant Ethernet (FTE)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnectivity and integrates seamlessly with Series C I\/O Termination Assemblies (IOTA). Its compact vertical design supports high-density cabinet installations, making it suitable for mission-critical industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Function\u003c\/td\u003e\n\u003ctd\u003eNetwork Control Firewall (CF9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eSeries C \/ Experion PKS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eCC-PCF901\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Support\u003c\/td\u003e\n\u003ctd\u003eFault Tolerant Ethernet (FTE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 9 RJ-45 ports (via IOTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps Auto-Sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraffic Filtering\u003c\/td\u003e\n\u003ctd\u003eHardware-based broadcast and multicast suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e5.5 × 16.2 × 14.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe CC-PCF901 is a critical component in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoil and gas refineries, chemical processing plants, and power generation facilities\u003c\/strong\u003e. It is deployed in all C300 controller installations to protect the control network from external traffic disturbances, ensuring that real-time control logic executes without interruption and maintaining high system availability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the CC-PCF901 differ from a standard IT firewall?\u003c\/strong\u003e\u003cbr\u003eUnlike traditional IT firewalls that rely on software-based filtering rules, the CC-PCF901 uses\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehardware-level traffic filtering\u003c\/strong\u003e, allowing only valid Experion PKS control communications. This ensures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ezero-latency performance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand deterministic operation for the C300 controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the CC-PCF901 required for redundant controller setups?\u003c\/strong\u003e\u003cbr\u003eYes, in redundant C300 systems, two CC-PCF901 modules are typically deployed—one for each controller. This provides independent, firewalled network paths, eliminating single points of failure and maintaining high system reliability.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48871729234172,"sku":"CC-PCF901","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CC-PCF901.jpg?v=1773989162","url":"https:\/\/www.electronicplc.com\/products\/control-firewall-module-cc-pcf901-honeywell","provider":"Electronic PLC","version":"1.0","type":"link"}