{"product_id":"control-panel-bachmann-wt205v","title":"Control Panel Bachmann WT205V","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWT205V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-performance analog output interface\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the Bachmann M1 system, engineered to drive\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 independent 4–20 mA HART-compatible field devices\u003c\/strong\u003e. Combining\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprecision signal generation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial-grade ruggedness\u003c\/strong\u003e, it ensures reliable process control in harsh environments, including oil \u0026amp; gas, chemical plants, wastewater treatment, and offshore installations. Its HART support enables\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebi-directional device diagnostics and configuration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edirectly through the analog loop.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWT205V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Channels Analog Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20 mA, HART-enabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM1 Backplane compatible, DeltaV compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogic Powe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 VDC, 150 mA (via local bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 g, ½ sine wave, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mm p-p (2–13.2 Hz), 0.7 g (13.2–150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAtmospheric Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985 Class G3 (Harsh\/Corrosive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOperational Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDrives\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHART-enabled field devices\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein oil \u0026amp; gas, chemical, and wastewater applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eextreme climates\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(arctic or desert) due to extended temperature range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnables\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eloop diagnostics and calibration monitoring\u003c\/strong\u003e, reducing maintenance downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Hardware Comparison\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUnlike standard AO208 modules, the WT205V adds\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eruggedization\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efull HART transparency\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial G3-class environmental conditions\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor harsh locations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor cabinets\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithout additional heating\/cooling systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the WT205V support multi-drop HART networks?\u003c\/strong\u003e\u003cbr\u003eA: It is primarily designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epoint-to-point 4–20 mA loops\u003c\/strong\u003e. HART multi-drop functionality depends on the master controller’s capabilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the field power isolated from the logic power?\u003c\/strong\u003e\u003cbr\u003eA: Yes,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12 V logic and 24 V field circuits are fully isolated\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto prevent electrical noise from affecting the central processor.\u003c\/p\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":48746805035260,"sku":"WT205V","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/WT205V_6056b3ab-fe4b-470f-89d7-20cabdee17a5.jpg?v=1770361974","url":"https:\/\/www.electronicplc.com\/products\/control-panel-bachmann-wt205v","provider":"Electronic PLC","version":"1.0","type":"link"}