{"product_id":"discrete-output-module-woodward-5464-654","title":"Discrete Output Module Woodward 5464-654","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5464-654\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density Discrete Output (DO) module developed by Woodward, Inc. for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol platform.\u003c\/p\u003e\n\u003cp\u003eThis module provides 32 independent digital output channels for controlling safety and automation devices such as solenoids, relays, and auxiliary equipment in turbine and engine control systems. It delivers millisecond-level response times synchronized with CPU control cycles, ensuring precise execution of control logic commands.\u003c\/p\u003e\n\u003cp\u003eThe module features a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epotentiometer-free, calibration-free architecture\u003c\/strong\u003e, enabling true plug-and-play replacement without requiring hardware adjustment or field recalibration. In the event of CPU communication loss, the built-in watchdog safety logic automatically de-energizes all outputs to place the system in a safe state.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5464-654\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiscrete Output (DO) Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlatform Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroNet Simplex \/ MicroNet Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 independent outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUpdate Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 ms CPU-synchronized cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports 2 FTM I\/O layouts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCalibration-free architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFail-Safe Logic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWatchdog protection; outputs de-energize on communication loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOnboard module health monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-speed MicroNet backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterchangeability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoftware-transparent replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTurbine and engine safety shutdown systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFuel valve and actuator control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlarm and annunciator output management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial automation and mechanical drive systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require special software?\u003c\/strong\u003e\u003cbr\u003eNo. The hardware is automatically recognized by MicroNet software, but logic configuration is done through GAP programming.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if CPU communication is lost?\u003c\/strong\u003e\u003cbr\u003eAll outputs automatically switch to a de-energized safe state.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan different FTM types be used?\u003c\/strong\u003e\u003cbr\u003eYes. The module supports multiple FTM wiring configurations for flexible field termination.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746772332796,"sku":"5464-654","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5464-6542.jpg?v=1772006490","url":"https:\/\/www.electronicplc.com\/products\/discrete-output-module-woodward-5464-654","provider":"Electronic PLC","version":"1.0","type":"link"}