{"product_id":"emerson-deltav-kj2101x1-ba-12p2690x012-i-o-interface","title":"Emerson DeltaV KJ2101X1-BA 12P2690X012 PROVOX I\/O Interface Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Emerson DeltaV KJ2101X1-BA (12P2690X012) is a specialized I\/O interface module designed to bridge legacy PROVOX subsystems with the modern DeltaV automation platform. This module enables industrial facilities, such as those in chemical processing, power generation, and pharmaceutical manufacturing, to integrate existing PROVOX I\/O files into the DeltaV architecture. By facilitating this migration, the unit allows for a phased, low-risk upgrade path that preserves existing field wiring investments while introducing advanced diagnostic capabilities and high-speed data throughput.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e Acts as a high-performance communication gateway, translating proprietary PROVOX I\/O bus protocols for compatibility with DeltaV controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e Designed to support redundant configurations, ensuring continuous process availability by allowing a standby unit to assume control seamlessly if the primary interface fails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad Compatibility:\u003c\/strong\u003e Interfaces directly with legacy PROVOX I\/O files, including those utilized in 20-series and 100-series hardware sets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Integrity:\u003c\/strong\u003e Utilizes rigorous error-checking algorithms to maintain signal precision across the legacy-to-modern interface boundary.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis interface module is intended for use in plant migration projects where legacy PROVOX control systems are being upgraded to DeltaV. It is ideal for environments requiring minimal downtime and the retention of existing field-side instrumentation and wiring.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ2101X1-BA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e12P2690X012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (via LocalBus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.0 W (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Rating\u003c\/td\u003e\n\u003ctd\u003e1 mm peak-to-peak (5-16 Hz); 0.5g (16-150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Rating\u003c\/td\u003e\n\u003ctd\u003e10g 1\/2 Sinewave for 11 msec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Designed for installation on a DeltaV 2-wide horizontal carrier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling:\u003c\/strong\u003e Ensure proper ESD (electrostatic discharge) precautions are taken when handling the module to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e Always ensure the system power is disconnected or the carrier is de-energized before inserting or removing the module to prevent electrical arcing or damage to the backplane pins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure the installation location meets the specified temperature and humidity ranges to maintain long-term reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Verify that the carrier is properly grounded according to DeltaV system installation standards to mitigate EMI and ensure signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eDoes this module support redundant configurations?\u003c\/h3\u003e\u003cp\u003eYes, the KJ2101X1-BA is designed to support redundant operation, allowing for a seamless transition to a standby module in the event of a primary unit failure.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with all PROVOX series?\u003c\/h3\u003e\u003cp\u003eThe module is specifically designed for compatibility with PROVOX 20-series and 100-series I\/O hardware sets.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":50528234471676,"sku":"KJ2101X1-BA 12P2690X012","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_41fd79f7-4272-4525-8af6-1f4985de5a46.jpg?v=1784781067","url":"https:\/\/www.electronicplc.com\/products\/emerson-deltav-kj2101x1-ba-12p2690x012-i-o-interface","provider":"Electronic PLC","version":"1.0","type":"link"}