{"product_id":"emerson-deltav-kj4001x1-ba3-12p3378x012-ve3051c0-carrier-module","title":"Emerson DeltaV KJ4001X1-BA3 12P3378X012 VE3051C0 2-Wide Carrier Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Emerson DeltaV KJ4001X1-BA3 (part number 12P3378X012, also identified as VE3051C0) is a 2-Wide Power\/Controller Carrier designed for the DeltaV Distributed Control System (DCS). This carrier provides the necessary mounting and power distribution infrastructure for DeltaV controllers and power supply modules. It is specifically engineered to support the DeltaV SIS (Safety Instrumented System) architecture, providing a robust interface for logic solvers and process control components.\u003c\/p\u003e\u003cp\u003eThis specific version of the carrier is identified by a small white rectangle printed on the board between the power supply and controller slots, ensuring compatibility with DeltaV SIS requirements.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2-Wide form factor for compact modular mounting.\u003c\/li\u003e\n\u003cli\u003eSupports integration of DeltaV power supply modules and controllers.\u003c\/li\u003e\n\u003cli\u003eCompatible with DeltaV SIS Logic Solvers for safety-critical applications.\u003c\/li\u003e\n\u003cli\u003eDesigned for high-reliability industrial process control environments.\u003c\/li\u003e\n\u003cli\u003eSupports online expansion and flexible installation configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOil and Gas: Refining and distribution process management.\u003c\/li\u003e\n\u003cli\u003eChemical Processing: Batch control and reaction monitoring.\u003c\/li\u003e\n\u003cli\u003ePower Generation: Electrical distribution and plant management.\u003c\/li\u003e\n\u003cli\u003eLife Sciences: Automated batch record and recipe management.\u003c\/li\u003e\n\u003cli\u003eMarine Automation: Shipboard control and engineering systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ4001X1-BA3 (12P3378X012 \/ VE3051C0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e2-Wide Power\/Controller Carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Rating\u003c\/td\u003e\n\u003ctd\u003e30 VDC, 8 A (Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (Non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Rating\u003c\/td\u003e\n\u003ctd\u003e10g, 1\/2 Sinewave for 11 msec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e1mm Peak-to-Peak (5 to 16 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirborne Contaminants\u003c\/td\u003e\n\u003ctd\u003eClass G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system is powered down before inserting or removing any modules from the carrier.\u003c\/li\u003e\n\u003cli\u003eVerify the carrier version (look for the white rectangle marking) to ensure compatibility with your specific SIS hardware.\u003c\/li\u003e\n\u003cli\u003eMount in an environment that meets the specified temperature and humidity ratings.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the carrier chassis to mitigate EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eWhen using with S-series hardware, ensure appropriate DeltaV SIS S-series adapters are utilized as required by the system architecture.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the difference between this carrier and older versions?\u003c\/h3\u003e\u003cp\u003eThe KJ4001X1-BA3 features a small white rectangle printed on the board between the power supply and controller slots. Older versions, which featured a white dot, are not compatible with DeltaV SIS logic solvers.\u003c\/p\u003e\u003ch3\u003eIs this carrier compatible with S-series I\/O?\u003c\/h3\u003e\u003cp\u003eYes, when using the appropriate DeltaV SIS S-series adapter, this carrier can interface with S-series power\/controller or I\/O carriers. Consult your system documentation for specific node configuration requirements.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":50878445879548,"sku":"KJ4001X1-BA3 12P3378X012 VE3051C0","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_433fea69-5895-4cac-b4ae-6c8592667fe1.jpg?v=1785583571","url":"https:\/\/www.electronicplc.com\/products\/emerson-deltav-kj4001x1-ba3-12p3378x012-ve3051c0-carrier-module","provider":"Electronic PLC","version":"1.0","type":"link"}