{"product_id":"emerson-deltav-kj4010x1-bg1-12p0830x072-localbus-extender","title":"Emerson DeltaV KJ4010X1-BG1 12P0830X072 Right LocalBus Extender","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Emerson DeltaV KJ4010X1-BG1 (12P0830X072) is a Right LocalBus Extender designed for the DeltaV scalable process control system. This module is essential for expanding the LocalBus backplane, enabling the interconnection of multiple I\/O carriers across different rows or enclosures within a control cabinet. It ensures high-speed data synchronization and maintains power distribution integrity across the extended bus, providing the necessary flexibility for large-scale distributed control system (DCS) deployments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFacilitates physical expansion of the DeltaV LocalBus backplane.\u003c\/li\u003e\n\u003cli\u003eEnables signal transition between carrier rows via dedicated cable assemblies.\u003c\/li\u003e\n\u003cli\u003eDesigned for high-availability industrial environments including oil, gas, and chemical processing.\u003c\/li\u003e\n\u003cli\u003eRated for operation in hazardous locations (Zone 2).\u003c\/li\u003e\n\u003cli\u003eConformal coating compliant with ISA-S71.04-1985 Class G3 for protection against corrosive contaminants.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is used in industrial automation environments where the I\/O count requires multiple carrier rows. It is commonly deployed in oil refineries, chemical processing plants, and mining operations where robust, reliable communication between the controller and remote I\/O is required.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ4010X1-BG1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e12P0830X072\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eRight LocalBus Extender\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocalBus Power Rating\u003c\/td\u003e\n\u003ctd\u003e12.6 VDC at 8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax System Length\u003c\/td\u003e\n\u003ctd\u003e6.5 meters (combined carriers and extenders)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e10g 1\/2 Sinewave for 11 msec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e1 mm P-P (5-16 Hz); 0.5g (16-150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure all power is de-energized before connecting or disconnecting LocalBus cables.\u003c\/li\u003e\n\u003cli\u003eThe module must be installed as the physical termination point on the right side of a carrier row.\u003c\/li\u003e\n\u003cli\u003eVerify that the total combined length of I\/O carriers and LocalBus extenders does not exceed 6.5 meters to maintain signal timing integrity.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD precautions to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003cli\u003eEnsure the environment meets the specified temperature and humidity ranges for optimal performance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\u003cp\u003eThe KJ4010X1-BG1 is certified for use in hazardous atmospheres, specifically II 3 G, Nemko 02ATEX431U, and EEx nA IIC T4, making it suitable for Zone 2 installations.\u003c\/p\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the KJ4010X1-BG1?\u003c\/h3\u003e\u003cp\u003eIt acts as a right-side interface to extend the DeltaV LocalBus, allowing you to connect I\/O carriers across multiple rows or cabinets while maintaining signal and power integrity.\u003c\/p\u003e\u003ch3\u003eCan this module be used in corrosive environments?\u003c\/h3\u003e\u003cp\u003eYes, the module is designed to meet ISA-S71.04-1985 Class G3 standards, providing resistance to corrosive airborne contaminants.\u003c\/p\u003e\u003ch3\u003eIs it safe to hot-swap this module?\u003c\/h3\u003e\u003cp\u003eNo. All power must be de-energized before connecting or disconnecting the LocalBus cables to prevent electrical damage or signal disruption.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":50618709442812,"sku":"KJ4010X1-BG1 12P0830X072","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_bf6b8962-732a-4172-828f-e230ff10b8f8.jpg?v=1784870312","url":"https:\/\/www.electronicplc.com\/products\/emerson-deltav-kj4010x1-bg1-12p0830x072-localbus-extender","provider":"Electronic PLC","version":"1.0","type":"link"}