{"product_id":"emerson-deltav-ve4002s1t1b2-kj3001x1-bg1-12p0557x162","title":"Emerson DeltaV VE4002S1T1B2 KJ3001X1-BG1 Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Emerson DeltaV VE4002S1T1B2 (KJ3001X1-BG1) is an 8-channel Digital Output Isolated Terminal Block engineered for the DeltaV distributed control system. This module acts as a vital interface between the control system logic and field-mounted actuators, providing reliable discrete signal switching. With its 12P0557X162 hardware revision, it is built to maintain signal integrity in demanding industrial environments such as oil and gas, chemical processing, and power generation, effectively isolating field-side transients from the controller backplane to prevent system-wide faults.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8-channel isolated discrete output configuration.\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between channels and system logic to eliminate ground loops.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED diagnostics for per-channel status monitoring and rapid fault detection.\u003c\/li\u003e\n\u003cli\u003eHot-swappable design for maintenance without process interruption.\u003c\/li\u003e\n\u003cli\u003eCompatible with DeltaV S-series and M-series controller environments.\u003c\/li\u003e\n\u003cli\u003eRobust electrical protection against electromagnetic interference (EMI).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is designed for use in mission-critical process automation applications where discrete control of field devices is required. Typical applications include the control of solenoid valves, relays, contactors, and other field actuators in hazardous or high-reliability industrial settings.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVE4002S1T1B2 (KJ3001X1-BG1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e12P0557X162\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the controller backplane is powered down before inserting or removing the module if the system environment does not support live-insertion protocols.\u003c\/li\u003e\n\u003cli\u003eHandle the module using ESD-safe practices to prevent damage to sensitive internal circuitry.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the DeltaV carrier to maintain the effectiveness of the galvanic isolation.\u003c\/li\u003e\n\u003cli\u003eRoute signal wiring away from high-voltage cables and sources of high electromagnetic interference to maintain signal accuracy.\u003c\/li\u003e\n\u003cli\u003eVerify that field load requirements do not exceed the module's rated switching capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs this module compatible with all DeltaV systems?\u003c\/h3\u003e\u003cp\u003eThe VE4002S1T1B2 is designed for integration into DeltaV S-series and M-series controller environments. Please verify your specific controller series and firmware compatibility before installation.\u003c\/p\u003e\u003ch3\u003eDoes this module support hot-swapping?\u003c\/h3\u003e\u003cp\u003eYes, this module is designed to be hot-swappable, allowing for replacement or maintenance without requiring a system shutdown, provided the carrier and system configuration support this feature.\u003c\/p\u003e\u003ch3\u003eWhat is the primary function of the isolation?\u003c\/h3\u003e\u003cp\u003eThe isolation provides galvanic separation between the field-side devices and the controller backplane. This protects the control system from electrical transients, surges, and ground loops originating from the field wiring.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":50617456492796,"sku":"VE4002S1T1B2 KJ3001X1-BG1 12P0557X162","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_3c8bbadb-a90a-4247-9a1f-06ee8b5913a4.jpg?v=1784869485","url":"https:\/\/www.electronicplc.com\/products\/emerson-deltav-ve4002s1t1b2-kj3001x1-bg1-12p0557x162","provider":"Electronic PLC","version":"1.0","type":"link"}