{"product_id":"emerson-deltav-ve4003s5b1-kj3002x1-bg2-12p1731x082-analog-input-module","title":"Emerson DeltaV VE4003S5B1 KJ3002X1-BG2 Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Emerson DeltaV KJ3002X1-BG2 (also identified as VE4003S5B1 or 12P1731X082) is a high-precision analog input module engineered for the DeltaV M-Series distributed control system. This module is specifically designed to interface with thermocouple and millivolt (mV) signals, providing direct measurement capabilities for temperature-critical industrial processes. By incorporating built-in cold junction compensation and advanced signal noise rejection, the module ensures high measurement accuracy without requiring external signal converters. It is built to withstand harsh industrial conditions, including exposure to corrosive gases, and is certified for use in hazardous environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Thermocouple Interface:\u003c\/strong\u003e Eliminates the need for external signal conditioning for standard thermocouple types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Diagnostics:\u003c\/strong\u003e Seamless integration with DeltaV system diagnostics for real-time health monitoring and fault detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion Resistance:\u003c\/strong\u003e Hardened circuitry compliant with ISA-S71.04 Class G3 standards for operation in environments with high concentrations of corrosive gases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Keying:\u003c\/strong\u003e Features B2 terminal block keying to prevent improper module insertion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Compatibility:\u003c\/strong\u003e ATEX Zone 2 (EEx nL IIC T4) certified for safe operation in potentially explosive atmospheres.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is widely utilized in process automation environments where precise temperature monitoring is essential. Typical applications include:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOil and gas refining processes.\u003c\/li\u003e\n\u003cli\u003eChemical reactor temperature monitoring.\u003c\/li\u003e\n\u003cli\u003ePower plant furnace and boiler control systems.\u003c\/li\u003e\n\u003cli\u003eGeneral industrial temperature acquisition requiring high noise immunity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ3002X1-BG2 \/ VE4003S5B1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e12P1731X082\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocalBus Power\u003c\/td\u003e\n\u003ctd\u003e12 VDC at 350 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Circuit Rating\u003c\/td\u003e\n\u003ctd\u003e5.5 VDC at 0.6 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent (Non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e10g half-sinewave for 11 msec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Limit\u003c\/td\u003e\n\u003ctd\u003e1mm P-P (5-16 Hz); 0.5g (16-150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Always ensure the system power is disconnected before installing or removing the module from the carrier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Precautions:\u003c\/strong\u003e Handle the module using proper electrostatic discharge (ESD) prevention techniques to avoid damaging sensitive internal components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeying:\u003c\/strong\u003e Verify that the terminal block keying matches the B2 position before attempting to seat the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure the installation location meets the specified temperature and humidity requirements. Avoid mounting in areas exceeding the vibration or shock limits defined in the specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded cabling for thermocouple inputs to minimize EMI interference, ensuring proper grounding practices are followed at the terminal block.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs this module hot-swappable?\u003c\/h3\u003e\u003cp\u003eYes, the KJ3002X1-BG2 supports hot-swapping within the DeltaV M-Series carrier, provided it is used in conjunction with a compatible system power supply such as the KJ1501X1-BC1.\u003c\/p\u003e\u003ch3\u003eWhat does the B2 keying indicate?\u003c\/h3\u003e\u003cp\u003eThe B2 keying is a physical safety feature on the module and terminal block that ensures the module is only inserted into a compatible slot, preventing electrical damage from incorrect hardware placement.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":50628200595708,"sku":"VE4003S5B1 KJ3002X1-BG2 12P1731X082","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_87075326-7d10-4db0-b18a-bbae2fa0188c.jpg?v=1784876666","url":"https:\/\/www.electronicplc.com\/products\/emerson-deltav-ve4003s5b1-kj3002x1-bg2-12p1731x082-analog-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}