{"product_id":"emerson-kj4001x1-ba2-ve3051co-12p1562x012-deltav-power-carrier-module","title":"Emerson KJ4001X1-BA2 VE3051CO 12P1562X012 DeltaV Power Controller Carrier","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Emerson KJ4001X1-BA2 (also identified as 12P1562X012 or VE3051CO) is a 2-wide power controller carrier designed specifically for the DeltaV M-Series automation system. This carrier serves as the essential mounting and electrical interface for power supplies and controllers, providing stable power distribution across the system LocalBus. It is engineered to support mission-critical industrial processes, ensuring reliable operation in environments such as petrochemical refining, power generation, and large-scale manufacturing.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned for seamless integration with DeltaV M-Series hardware.\u003c\/li\u003e\n\u003cli\u003eProvides a secure, high-capacity interface for power distribution.\u003c\/li\u003e\n\u003cli\u003eSupports a maximum input of 30 VDC at 8 A.\u003c\/li\u003e\n\u003cli\u003eRobust construction suitable for demanding industrial environments.\u003c\/li\u003e\n\u003cli\u003eCompatible with standard DeltaV LocalBus configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis carrier is intended for use in DeltaV control systems where stable power and controller mounting are required. It is commonly deployed in distributed control system (DCS) architectures for process automation, safety-critical monitoring, and industrial facility management.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ4001X1-BA2 (12P1562X012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eDeltaV M-Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Controller 2-Wide Carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e30 VDC at 8 A (Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent (Non-Condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Rating\u003c\/td\u003e\n\u003ctd\u003eII 3 G \/ EEx nA IIC T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX Certification\u003c\/td\u003e\n\u003ctd\u003eNemko No. 02ATEX431U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirborne Contaminants\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e10g 1\/2 Sinewave for 11 msec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e1 mm P-P (5-16 Hz); 0.5g (16-150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Bus Length\u003c\/td\u003e\n\u003ctd\u003e6.5 meters (Total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system is completely de-energized before attempting to install or remove the carrier or any associated LocalBus cables.\u003c\/li\u003e\n\u003cli\u003eThe carrier must be mounted in accordance with DeltaV M-Series hardware specifications to ensure proper cooling and electrical grounding.\u003c\/li\u003e\n\u003cli\u003eTotal length of I\/O carriers and LocalBus Extenders must not exceed 6.5 meters to maintain signal integrity and power stability.\u003c\/li\u003e\n\u003cli\u003eUse KJ4001X1-FA1 module covers on all unused slots to prevent environmental degradation and ingress of contaminants.\u003c\/li\u003e\n\u003cli\u003eHandle with care to avoid electrostatic discharge (ESD) damage to sensitive electronic components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the KJ4001X1-BA2?\u003c\/h3\u003e\u003cp\u003eThe KJ4001X1-BA2 acts as a mounting base and power distribution interface for DeltaV M-Series controllers and power supplies, ensuring they are correctly powered and connected to the system LocalBus.\u003c\/p\u003e\u003ch3\u003eCan this carrier be used in hazardous locations?\u003c\/h3\u003e\u003cp\u003eYes, it is rated for hazardous atmosphere locations (II 3 G \/ EEx nA IIC T4) and carries the Nemko 02ATEX431U certification.\u003c\/p\u003e\u003ch3\u003eWhat should I do with unused slots on the carrier?\u003c\/h3\u003e\u003cp\u003eTo maintain the integrity of the hardware and protect against environmental factors, all unused slots must be covered using the KJ4001X1-FA1 module cover.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":50517470052604,"sku":"KJ4001X1-BA2 VE3051CO 12P1562X012","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_ef28dc2a-de54-422d-937f-60cf726a4e71.jpg?v=1784769881","url":"https:\/\/www.electronicplc.com\/products\/emerson-kj4001x1-ba2-ve3051co-12p1562x012-deltav-power-carrier-module","provider":"Electronic PLC","version":"1.0","type":"link"}