{"product_id":"f3yd64-1p-yokogawa-transistor-output-module-new-original-stock","title":"F3YD64-1P Yokogawa Transistor Output Module | New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa F3YD64-1P\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eF3YD64-1P\u003c\/strong\u003e Transistor Output Module, operates as a dedicated hardware component for high-density digital signal switching within FA-M3 sequence CPU system platforms. This module provides direct electrical execution of control logic by driving field-level actuators through 64 individual output points.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eF3YD64:\u003c\/strong\u003e Base model designation indicating a 64-point transistor output configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-1P:\u003c\/strong\u003e Hardware revision\/type identifier specifying the isolated transistor output architecture for the FA-M3 series.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3YD64-1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.89 x 8.32 x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e275 mA (5 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Points\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Line\u003c\/td\u003e\n\u003ctd\u003e8 points \/ common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Method\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (1 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Load Voltage\u003c\/td\u003e\n\u003ctd\u003e12 to 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e12 to 24 VDC, 95 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe F3YD64-1P is engineered to maintain high signal integrity in dense I\/O applications. By utilizing photocoupler isolation, the module prevents electrical transients from the field-side wiring from propagating back to the control-side backplane, ensuring stable communication velocity across the FA-M3 bus. The 8-point common line configuration allows for segmented power distribution, enabling users to isolate different load groups while maintaining common reference points for logic control. This architecture supports I\/O density scaling essential for complex machine control sequences.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this module be installed in a hot-swap environment?\u003c\/p\u003e\n\u003cp\u003eA: No. Power must be isolated from the FA-M3 backplane before installing or removing the F3YD64-1P module to prevent potential damage to the bus communication interface.\u003c\/p\u003e\n\u003cp\u003eQ: How should the common line be configured for the 8-point grouping?\u003c\/p\u003e\n\u003cp\u003eA: Each group of 8 points shares a common return; ensure that the total current draw for each group does not exceed the hardware-rated limits to prevent thermal degradation of the common trace.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the module is securely latched into the FA-M3 base unit. Use the locking tabs to maintain DIN-rail mounting stability and prevent disconnection due to vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Keep load-side wiring away from high-voltage AC paths to prevent induced noise. Ensure external power supply polarity (12 to 24 VDC) is verified before making physical connections to the terminal block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Terminate cable shields at the designated ground terminal on the base unit to maximize surge voltage protection and minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning:\u003c\/strong\u003e Prior to full system integration, perform a continuity check on all 64 output points to ensure that the sink-type transistor logic corresponds with the field device requirements.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49177156616444,"sku":"F3YD64-1P","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/F3YD64-1P.jpg?v=1781055595","url":"https:\/\/www.electronicplc.com\/products\/f3yd64-1p-yokogawa-transistor-output-module-new-original-stock","provider":"Electronic PLC","version":"1.0","type":"link"}